Local Installation

Dip Switch settings for SMB CAT5 (F1DP104Aea, F1DP108Aea and F1DP116Aea).

BANK-DIP-Switch-Configuration Chart

DIP SWITCH

 

 

BANK ADDRESS

1

2

3

4

 

N/A

N/A

N/A

N/A

BANK 00 Primary

 

 

 

 

(SMB KVM-over-IP Switch)

UP

DOWN

DOWN

DOWN

BANK 01 Secondary

DOWN

UP

DOWN

DOWN

BANK 02 Secondary

UP

UP

DOWN

DOWN

BANK 03 Secondary

DOWN

DOWN

UP

DOWN

BANK 04 Secondary

UP

DOWN

UP

DOWN

BANK 05 Secondary

DOWN

UP

UP

DOWN

BANK 06 Secondary

UP

UP

UP

DOWN

BANK 07 Secondary

DOWN

DOWN

DOWN

UP

BANK 08 Secondary

UP

DOWN

DOWN

UP

BANK 09 Secondary

DOWN

UP

DOWN

UP

BANK 10 Secondary

UP

UP

DOWN

UP

BANK 11 Secondary

DOWN

DOWN

UP

UP

BANK 12 Secondary

UP

DOWN

UP

UP

BANK 13 Secondary

DOWN

UP

UP

UP

BANK 14 Secondary

UP

UP

UP

UP

BANK 15 Secondary

Example:

Three SMB CAT5 16-Port KVM Switches (F1DP116Aea) are daisy-chained together with an SMB KVM-over-IP 1x16 Switch (F1DP116Gea) to manage up to 64 servers. The DIP switches on the secondary units are each set to a unique BANK address (between 01 and 03).