U.S. and Canadian Installations

MT1828E Single Phase Installation

Electrical Connection

 

 

 

U.S. and Canadian Installations

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

 

 

 

 

Supply

L2

208/240

 

Oven

 

 

 

 

 

 

 

 

L1

 

 

 

 

 

 

 

 

 

 

N

120

208-240

 

 

 

 

 

 

 

Supply

L2

120

Oven

 

 

MT1828E Single Phase

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

 

 

MT1828G

 

 

 

L2

 

208/240

 

 

 

 

 

Supply

L3

 

Oven

 

 

 

 

 

 

 

 

 

 

 

 

 

MT1828E Three Phase Delta System

 

 

General Export and Australian Installations

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

 

L1

 

 

 

 

L2

 

208/240

 

 

 

 

 

 

Supply

L3

 

 

Oven

Supply

N

220/240

Oven

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MT1828G

 

 

MT1828E Three Phase Delta System

 

 

 

 

 

L1

 

 

 

 

 

 

L1

 

 

 

L2

415/380

415/

240/

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply L3

415/380

380

Oven

 

 

220/230/240

 

 

 

 

 

 

220

 

Supply

L2

Oven

N

 

 

 

 

 

 

MT1828E Single Phase

 

MT1828E Three Phase WYE System

 

 

 

 

 

Figure 13

 

 

 

 

 

 

 

 

 

 