Blodgett XR8-G Installation, Gas Connection, Pressure Regulation And Testing, Inlet Pressure

Models: XR8-G

1 39
Download 39 pages 3.65 Kb
Page 12
Image 12
PRESSURE REGULATION AND TESTING

Inlet Pressure Installation

Gas Connection

PRESSURE REGULATION AND TESTING

XR8-G ovens are rated at 110,000 BTU/Hr. (32 kW) (116 MJ/hr). Each oven has been adjusted at the factory to operate with the type of gas specified on the rating plate.

Inlet Pressure

 

Natural

Propane

 

 

 

 

 

 

 

 

Min

 

Max

Min

 

Max

 

 

 

 

 

 

 

W.C.

6.0

 

14.0

11.0

 

14.0

 

 

 

 

 

 

 

kPa

1.2

 

3.5

2.7

 

3.5

 

 

 

 

 

 

Manifold Pressure

 

 

 

 

 

 

 

Natural

Propane

 

 

 

 

 

W.C.

 

3.5

 

10.0

 

 

 

 

 

kPa

 

.87

 

2.5

DInlet Pressure --- the pressure of the gas before it reaches the oven.

DManifold Pressure --- the pressure of the gas as it enters the main burner(s).

DMin --- the minimum pressure recommended to operate the oven.

D Max --- the maximum pressure at which the manufacturer warrants the oven’s operation.

Each oven is supplied with a regulator to maintain the proper gas pressure. The regulator is essen- tial to the proper operation of the oven and should not be removed. It is preset to provide the oven with 3.5” W.C. (.87 kPa) for natural gas and 10.0” W.C. (2.5 kPa) for Propane at the manifold.

DO NOT INSTALL AN ADDITIONAL REGULATOR WHERE THE OVEN CONNECTS TO THE GAS SUPPLY UNLESS THE INLET PRESSURE IS ABOVE MAXIMUM.

Prior to connecting the oven, gas lines should be thoroughly purged of all metal filings, shavings, pipe dope, and other debris. After connection, the oven should be checked for correct gas pressure.

The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45kPa).

The oven must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas piping system at test pressures equal or less than 1/2 psig (3.45kPa).

Gas Connection

 

2.78” (71 mm)

 

 

53.62 (1362)

 

Gas Connection

 

37.83 (961mm)

 

Gas Connection

SIDE VIEW WITH STAND

SIDE VIEW WITH OPTIONAL PROOFER

Figure 2

8

Page 12
Image 12
Blodgett XR8-G manual Installation, Gas Connection, Pressure Regulation And Testing, Inlet Pressure, Natural, Propane