Blodgett XR8-G Plumbing and Electrical Connections, Installation, Plumbing Connections, Model

Models: XR8-G

1 39
Download 39 pages 3.65 Kb
Page 14
Image 14
Plumbing and Electrical Connections

PLUMBING CONNECTIONS Installation

Plumbing and Electrical Connections

PLUMBING CONNECTIONS

Water Connections WARNING!!

Plumbing connections must comply with applicable sanitary, safety and plumbing codes.

Water Connections

Water supply should meet the following condi- tions. Consult your local water company before installing the oven.

DHardness of 4-6 grains per gallon (100ppm max) D PH of 6.5 to 8.0

D Chlorides less than 30 PPM

1.Connect the cold water supply to the 3/4” MGHT connection on the back of the oven with the water line provided. Supply pressure should be 30 to 75 psi (207 to 517 kPa) when the steam solenoid is open. The water regula- tor on the oven itself must be set to 15 psi (103 kPa) when the steam solenoid is open.

Drain Connections

1.Connect drain line to the 3/4” NPT drain con- nection on the back of the oven.

2.Route the drain line to a floor drain. Allow a 1” air gap between the drain line and the floor drain.

NOTE: When the oven is stacked on a proofer a separate drain line should be installed. If a second drain line is not possible, pro- vide a vent opening in the drain line above the oven drain connection. Be sure to pro- vide enough drop so the oven drain will not flood the proofer cabinet.

ELECTRICAL CONNECTIONS

Wiring diagrams are located in the right bodyside.

This oven is supplied for connection to a 120 volt grounded circuit. The electric motor, indicator lights and related switches are connected through the 6’ electric supply cord found at the rear of the oven.

NOTE: When the oven is installed with a proofer a separate 120 volt grounded circuit will be required.

Drain Connections WARNING!!

This appliance is equipped with three prong grounding type plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. DO NOT cut or remove the grounding prong from this plug.

THE BLODGETT OVEN COMPANY CANNOT AS- SUME RESPONSIBILITY FOR LOSS OR DAMAGE SUFFERED AS A RESULT OF IMPROPER INSTAL- LATION.

ELECTRICAL SPECIFICATIONS

Model

Hz

Volts

Phase

Amps

Electrical Connection

 

 

 

 

 

(minimum size)

 

 

 

 

 

 

XR8-G

60

120

1

5

Cord set provided

 

 

 

 

 

 

10

Page 14
Image 14
Blodgett XR8-G Plumbing and Electrical Connections, Installation, Plumbing Connections, Water Connections, Model, Volts