Basic Saw Operations (continued)

Miter Detent Override

The miter detent override feature allows the detent action to be locked out, allowing for micro adjust- ments at any miter angle. When the desired miter angle is to close to a standard mitering angle that has a detent slot, this feature prevents the wedge on the miter arm from slipping into the detent slot on the base.

To Engage:

1.Lift and hold the miter detent lever.

2.Push the detent override clip forward and latch in place over edge. Release miter detent lever.

3.Move miter arm to any position on the miter scale.

4.Lock the miter lock knob to retain miter position.

To Disengage:

Loosen miter lock knob and lift the miter detent lever to release the detent override clip. The clip should automatically disengage.

Detent

Override Clip

Miter

Lock Knob

Miter

Detent Lever

Figure: Detent Override

Microfine Miter Adjustment

System

This feature allows you to move the turntable by very small increments up to 2 degrees to the left or right of the detent angles (except 60° detent) to reach to the desired miter angle.

1. Move the table to the detented angle that is to be

adjusted (Figure 1).

 

 

 

 

 

 

 

0

85

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

80

 

 

5

55

 

 

70

75

 

 

 

60

65

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

.5

 

 

10

 

 

 

31

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

.6

 

20

15

 

 

 

 

35

30 25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Miter Scale

2.

The miter detent lever's red override feature

 

MUST be engaged, as described above.

3.

Push the Microfine Adjustment knob forward to

Angle Detents

Indicator

Bevel

Lock

'ENGAGED' position. This engages the system

into the detent slot (Figure 2).

Note: You may have to rotate the table slightly to

engage the system.

Figure 1. Miter Scale Indicator

Microfine

Adjustment

4.

Turn knob until pointer comes to desired angle.

• Rotating the knob forward causes the table to

 

rotate to the left.

Rotating the knob backward causes the table to

 

rotate to the right.

5.

Use miter lock knob to lock table in place before

 

cutting.

6.

To release table from Microfine Adjustment

 

System, simply pull knob away from table until in

 

snaps into 'OFF' position.

knob

Miter

Lock Knob

OFF ENGAGED

NOTE: Microfine must be returned to the ‘OFF’

position in order to use the standard detent system.

Figure 2. Microfine Adjustment System

24.

Page 24
Image 24
Bosch Power Tools 4410L manual Miter Detent Override, Microfine Miter Adjustment System, To Engage, To Disengage