420 Fabric OS Administrator’s Guide
53-1001763-02
Displaying bottleneck detection configuration details
18
1. Connect to the switch to which the target port belongs and log in as admin.
2. Enter the bottleneckmon --exclude command to exclude the port from bottleneck detection.
To later include the port, enter the bottleneckmon --include command.
Example
switch:admin> bottleneckmon --exclude 4

Displaying bottleneck detection configuration details

Using the following procedure, you can display details of the bottleneck detection configuration,
including the following:
Whether the feature is enabled
Switch-wide alerting parameters
Port-specific alerting parameters
Excluded ports
1. Connect to the switch and log in as admin.
2. Enter the bottleneckmon --status command to display the details of bottleneck detection
configuration for the switch.
Example
switch:admin> bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide alerting parameters:
============================
Alerts - Yes
Latency threshold for alert - 0.100
Congestion threshold for alert - 0.800
Averaging time for alert - 300 seconds
Quiet time for alert - 300 seconds
Excluded ports:
===============
Port
====
12
13
14

Changing bottleneck alert parameters

When you enable bottleneck detection, you can configure alert parameters that apply to every port
on the switch. After you enable bottleneck detection, you can change the alert parameters on all
eligible ports on the switch or on individual ports. You can also change the alert parameters on
ports that have been excluded from bottleneck detection.