504 Fabric OS Administrator’s Guide
53-1001763-02

Fabric configurations for interconnectivity

A
state rev owner
known v520 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 010e00; 3;10:00:00:00:00:01:00:00;10:00:00:00:00:00:01:00;
Fabric Port Name: 20:0e:00:60:69:e2:18:b6
Permanent Port Name: 10:00:00:00:00:01:00:00
Port Index: 14
Share Area: No
Device Shared in Other AD: No
Switch entry for 3
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 03f001; 2,3;10:00:00:00:c9:44:54:04;20:00:00:00:c9:44:54:04;
FC4s: FCP
NodeSymb: [36] "Emulex LP9002 FV3.92A2 DV5-5.10A10 "
Fabric Port Name: 50:00:51:e3:70:9a:3d:e8
Permanent Port Name: 10:00:00:00:c9:44:54:04
Port Index: na
Share Area: No
Device Shared in Other AD: No
Switch entry for 4
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 04f002; 3;10:00:00:00:00:03:00:00;10:00:00:00:00:00:03:00;
Fabric Port Name: 50:06:06:91:23:45:6a:13
Permanent Port Name: 10:00:00:00:00:03:00:00
Port Index: na
Share Area: No
Device Shared in Other AD: No

All of the devices from both LSANs should appear in the output. If the devices do not appear in

the output, issue the cfgShow command to verify your zone configuration. Use the cfgactvshow

command to display the zone configuration currently in effect. The following example

illustrates the use of cfgactvshow.

switch:admin> cfgactvshow
Effective configuration:
cfg:test
zone:lsan_san
10:00:00:00:00:03:00:00
10:00:00:00:00:01:00:00
zone:lsan_test
50:06:01:60:38:e0:0b:a4
10:00:00:00:c9:44:54:04

7. Log into the FC router and run the lsanZoneShow -s command to verify FIDs and devices to be

shared among LSANs.