10. Adjustments
10-4. Removal of the fixed knife and the movable knife
Note:
Turn off the power switch.
■Removal of the fixed knife
Notch
qw
Belows rail
r
e r
u
t
i
y
1.Remove
2.Remove clamping screws r and then tilt the machine head.
NOTE:
At this time, adjust the position of the machine head so that it is aligned with the notch in the bellows rail.
3.Remove clamping bolt t and then bobbin case holder position bracket y.
4.Remove
¡When the fixed knife i becomes blunt, sharpen it as illustrated at right.
■Removal of the movable knife
|
| q |
|
r |
|
|
|
e | t | w | y |
t
y
u
1.Remove
2.Remove clamping screw e and then presser foot assembly r.
3.Turn the pulley and stop the needle bar at its highest position.
4.Remove screw t and then needle y.
5.Push thread trimming rod t in the arrowed direction and stop where
6.Remove
Note:
To reassemble, reverse the above procedures.