12. Table of error code

Error code

Contents

Reset

 

 

 

E – 800

EMERGENCY STOP button pressed

Yes

 

 

 

E – 801

EMERGENCY STOP button pressed during sewing

Yes

 

 

 

E – 802

EMERGENCY STOP button pressed during programming

No

 

 

 

E – 803

EMERGENCY STOP button pressed during programming

Yes

 

 

 

E – 810

EMERGENCY STOP button is not connected

No

E – 820

No air, or air chuck is turned off

Yes

E – 821

No air, or air chuck is turned off

No

E – 830

X right overtravel switch activated

No

 

 

 

E – 840

X left overtravel switch activated

No

 

 

 

E – 850

Y up overtravel switch activated

No

 

 

 

E – 860

Y down overtravel switch activated

No

 

 

 

E – 870

X motor problem

No

E – 880

Y motor problem

No

E – 890

Machine head motor problem

No

E – 900

Outer work clamp cylinder malfunction or sensor malfunction

No

 

 

 

E – 901

Inner work clamp cylinder malfunction or sensor malfunction

No

 

 

 

E – 902

Gauge forward/back cylinder malfunction or sensor malfunction

No

 

 

 

E – 903

Base 10 cylinder malfunction or sensor malfunction

No

 

 

 

E – 910

X axis positioning error

No

 

 

 

E – 920

Y axis positioning error

No

 

 

 

E – 960

Clamp-in sensor malfunction

No

E – 970

Clamp malfunction

No

*If the primary-side voltage is lower than the rated level at low temperatures, the error message “E-890” may appear at the sewing start. If this happens, set DIP switch A-7 to ON.