10. SUMMARY OF DIP SWITCHES
10-2. Circuit board DIP switches
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the face plate of the control box. Touching areas where high voltages are present can result in severe injury.
The ON/OFF positions of the DIP switches inside the front panel are checked only once when the power is turned on. Any changes to the DIP switch positions will not be effective until the power is switched off and back on again.
Only one of DIP switch No.1, 2 and 3 is effective at any one time. They are effective in the order 1, 2, 3.
No. | ON/OFF | Description | ||
1 | ON | Data initialization | ||
OFF | Normal | |||
|
| |||
2 | ON | Input check | ||
OFF | Normal | |||
|
| |||
3 | ON | Output check | ||
OFF | Normal | |||
|
| |||
4 | *1 | ON | Upper gimp guide present | |
OFF | Upper gimp guide not present | |||
|
| |||
5 | *2 | ON | Upper thread nipper present | |
OFF | Upper thread nipper not present | |||
|
| |||
6 | ON | Upper and lower thread trimming | ||
OFF | Upper thread trimming | |||
|
| |||
7 | ON | Material is remains pressed after sewing | ||
OFF | Material is released after sewing | |||
|
| |||
8 | ON | Needle bar returns to home position after set number of pieces sewn | ||
OFF | Needle bar always returns to home position after each piece sewn | |||
|
| |||
|
|
|
|
*1 The version of the PROM is given as “E1” or later.
*2 The version of the PROM is given as “D1” or later.
If the stitch length has been set to 39 mm or greater, it will be automatically changed to 38 mm if DIP switch No. 6 is changed to ON.
* The machine is shipped from the factory with the DIP switches set as follows.
1193Q
57