3. INSTALLATION
3-9. Connecting the ground wires and the wirings
1106Q
| (2) |
| (7) |
|
|
|
|
|
|
|
| ||
| (1) |
| (3) |
|
|
|
|
| (4) |
|
|
| |
|
|
| (6) |
|
|
|
|
|
| (5) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1105Q | Power switch installation position | ||
1104Q |
| |||||
|
|
|
|
1.Connect the foot controller cable (1) and the motor cable (2) to the control box.
2.Install the power switch (3) to the underside of the work table with the two screws (4).
3.Clamp the foot controller cable (1) with the two cable clips (5) and then secure the cable clips (5) with the screws (6).
4.Install the motor cable (2) and the power switch cable to the underside of the work table with the staple (7).
1107Q |
| (12) | 1109Q | (16) |
|
|
|
|
|
| |
|
| (11) |
|
|
|
|
| (16) | (8) |
| (17) |
|
|
| Needle | ||
|
|
| (9) |
| |
|
| (13) | White | position sensor | |
|
|
| |||
|
| (10) | Blue | 6P | |
|
|
| Black | ||
|
|
|
| 6P | |
|
|
| (17) | White | 6P |
|
|
|
| White | 12P |
|
|
|
| White | (18) |
|
|
|
| (19) | 4P |
| (15) | (14)(10) |
|
|
|
1108Q | (15) |
| 1110Q | 1111Q | |
|
| ||||
|
|
|
|
|
|
5.Pass the cable and air tube which are coming out of the feed bracket (8) and the left side of the bed stand (9) through the cable hole (10) in the work table.
6.Pass the cable and air tube which are coming out of the belt cover (11) and the machine head (12) through the cable hole (13) in the work table.
7.Insert each of the connectors into the connectors on the control box. (Refer to the illustration above.)
8.Pass the cables and air hoses through the two cable holders (14), and then secure the cable holders (14) to the underside of the work table with the two screws (15).
9.The ground wires (16), (17) should always be connected to the control box.
10.Connect the accessory ground wire (18) to the ground terminal of the control box and to the table leg installation bolt. Note: If the ground wire is not connected,
11.Connect the power switch connector (19) to the motor.
8