3-9. Connecting the ground wires and the wirings

3. INSTALLATION

3-9. Connecting the ground wires and the wirings

1106Q

 

(2)

 

(7)

 

 

 

 

 

 

 

 

 

(1)

 

(3)

 

 

 

 

 

(4)

 

 

 

 

 

 

(6)

 

 

 

 

 

 

(5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1105Q

Power switch installation position

1104Q

 

 

 

 

 

1.Connect the foot controller cable (1) and the motor cable (2) to the control box.

2.Install the power switch (3) to the underside of the work table with the two screws (4).

3.Clamp the foot controller cable (1) with the two cable clips (5) and then secure the cable clips (5) with the screws (6).

4.Install the motor cable (2) and the power switch cable to the underside of the work table with the staple (7).

1107Q

 

(12)

1109Q

(16)

 

 

 

 

 

 

 

 

(11)

 

 

 

 

 

(16)

(8)

 

(17)

 

 

 

Needle

 

 

 

(9)

 

 

 

(13)

White

position sensor

 

 

 

 

 

(10)

Blue

6P

 

 

 

Black

 

 

 

 

6P

 

 

 

(17)

White

6P

 

 

 

 

White

12P

 

 

 

 

White

(18)

 

 

 

 

(19)

4P

 

(15)

(14)(10)

 

 

 

1108Q

(15)

 

1110Q

1111Q

 

 

 

 

 

 

 

 

5.Pass the cable and air tube which are coming out of the feed bracket (8) and the left side of the bed stand (9) through the cable hole (10) in the work table.

6.Pass the cable and air tube which are coming out of the belt cover (11) and the machine head (12) through the cable hole (13) in the work table.

7.Insert each of the connectors into the connectors on the control box. (Refer to the illustration above.)

8.Pass the cables and air hoses through the two cable holders (14), and then secure the cable holders (14) to the underside of the work table with the two screws (15).

9.The ground wires (16), (17) should always be connected to the control box.

10.Connect the accessory ground wire (18) to the ground terminal of the control box and to the table leg installation bolt. Note: If the ground wire is not connected, mis-operation due to discharges of static electricity may occur.

11.Connect the power switch connector (19) to the motor.

8

RH-9800

Page 14
Image 14
Brother DH4-B980 Connecting the ground wires and the wirings, Installation, Power switch installation position