Bryant 542J, 549B manual MODEL NUMBER NOMENCLATURE — 548F UNITS, ODS Model Number, 548F036-060

Models: 549B 548F 542J

1 122
Download 122 pages 32.45 Kb
Page 18
Image 18
MODEL NUMBER NOMENCLATURE — 548F UNITS

120

MODEL NUMBER NOMENCLATURE — 548F UNITS

(ODS Model Number)

548F E X 090 000 AA

548F036-

548F – Single-Package

Heat Pump

Unit

Voltage Designation

E – 460-3-60

J – 208/230-1-60†

P – 208/230-3-60

T – 575-3-60

XNo Heat Installed.

(Field-installed electric heaters available.)

Nominal Tons

 

036 –

3

090

7-1/2

048 –

4

102

8-1/2

060 –

5

120

10

072 –

6

 

 

LEGEND

ODS — Order Distribution System

*Refer to Trade Price Sheets or contact your local representative for specific information regarding which options are available on which units.

†Single-phase is only available on 036-060 size units.

NOTE: The example model number 548FEX090000AA designates a 71/2 ton 460-3-60 volt electric heat pump unit with factory-installed economizer.

Factory-Installed Options*

Electric Heaters

000 – No factory-installed electric heaters

ARI* CAPACITY RATINGS

548F036-060

 

 

 

 

 

 

 

COOLING

 

 

HEATING

 

 

 

 

 

 

 

 

 

 

 

 

 

(High Temp)

 

 

 

SOUND

UNIT

NOMINAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEER†

 

 

 

 

 

 

 

 

 

RATING

548F

TONS

 

 

Capacity

 

 

Capacity

 

 

 

 

 

 

 

Belt

 

 

Direct

 

 

HSPF

 

(decibels)

 

 

 

 

 

(Btuh)

 

 

(Btuh)

 

 

 

 

 

 

 

 

 

 

 

Drive

 

 

Drive

 

 

 

 

 

 

 

 

036

 

3

 

 

35,600

10.20

 

 

10.00

 

34,400

 

 

 

6.7

84

048

 

4

 

 

46,500

10.00

 

 

9.70

 

46,500

 

 

 

7.0

80

060

 

5

 

 

57,000

10.00

 

 

9.90

 

57,000

 

 

 

7.5

82

 

 

 

 

 

 

 

548F072-120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING

HEATING

 

 

HEATING

 

 

 

 

 

SOUND

UNIT

 

NOMINAL

 

(High)

 

 

(Low)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IPLV**

 

RATING

548F

 

TONS

Capacity

 

EER

Capacity

 

COP

 

Capacity

 

COP

 

 

 

(decibels)

 

 

 

 

 

 

 

 

 

 

 

 

 

(Btuh)

 

 

(Btuh)

 

 

 

(Btuh)

 

 

 

 

 

 

 

072††

 

6

70,000

 

9.05

72,400

 

 

3.20

 

42,000

 

2.14

 

 

82

090††

 

71/2

86,000

 

9.00

78,000

 

 

3.00

 

39,000

 

1.80

 

9.3

 

86

102††

 

81/2

96,000

 

8.90

96,000

 

 

3.00

 

55,000

 

2.00

 

8.85

 

86

120††

 

10

112,000

 

9.00

105,000

 

 

3.10

 

59,000

 

2.00

 

9.0

 

84

 

 

LEGEND

COP

Coefficient of Performance

db

dry bulb

EER

Energy Efficiency Ratio

HSPF — Heating Seasonal Performance Factor

IPLV

Integrated Part-Load Values

SEER

Seasonal Energy Efficiency Ratio

wb

wet bulb

*Air Conditioning and Refrigeration Institute.

†Applies only to units with capacity of 60,000 Btuh or less. **The IPLV applies only to 2-stage heat pump units.

††Not ASHRAE 90.1-99 compliant.

NOTES:

1.Rated in accordance with ARI Standards 210/240-95 and 270-95.

2.Ratings are net values, reflecting the effects of circulating fan heat.

3. Ratings are based on:

Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature and 95 F db air entering outdoor unit.

IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F db out- door entering-air temperature.

High-Temp Heating Standard: 70 F db indoor entering-air temperature and 47 F db, 43 F wb outdoor entering-air temperature.

Low-Temp Heating Standard: 70 F db indoor entering-air temperature and 17 F db, 15 F wb outdoor entering-air temperature.

18

Page 18
Image 18
Bryant 542J MODEL NUMBER NOMENCLATURE — 548F UNITS, ODS Model Number, 548F036, Ari* Capacity Ratings, 548F E X 090 000 AA