Bryant 542J 548F036-120, PERFORMANCE DATA cont, INSTANTANEOUS AND INTEGRATED HEATING RATINGS cont

Models: 549B 548F 542J

1 122
Download 122 pages 32.45 Kb
Page 30
Image 30
1800

548F036-120

PERFORMANCE DATA (cont)

INSTANTANEOUS AND INTEGRATED HEATING RATINGS (cont)

548F072

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

Cfm

 

 

 

 

 

 

 

 

Air Temperature Entering Outdoor Coil (F)

 

 

 

 

 

 

 

 

 

Air

(Standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

10

 

17

 

30

 

 

 

40

47

 

 

 

50

 

60

(F db)

Air)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

Cap.

37.8

 

32.2

43.9

 

40.3

48.3

 

44.1

58.0

 

50.8

66.2

 

66.2

72.3

 

72.3

 

75.2

 

75.2

86.0

 

86.0

 

 

kW

4.72

4.97

5.16

5.58

 

5.96

6.25

 

6.40

6.95

 

 

 

 

 

 

55

2400

Cap.

37.9

 

32.2

44.0

 

40.4

48.5

 

44.2

58.4

 

51.2

66.6

 

66.6

72.8

 

72.8

 

75.9

 

75.9

87.0

 

87.0

 

kW

4.55

4.76

4.92

5.28

 

5.57

5.81

 

5.93

6.38

 

 

 

 

 

 

 

3000

Cap.

38.0

 

32.3

44.0

 

40.4

48.5

 

44.3

58.5

 

51.3

66.9

 

66.9

73.1

 

73.1

 

76.2

 

76.2

87.5

 

87.5

 

 

kW

4.46

4.64

4.78

5.09

 

5.35

5.56

 

5.67

6.07

 

 

 

 

 

 

 

1800

Cap.

37.3

 

31.7

43.6

 

40.0

48.1

 

43.9

57.5

 

50.4

65.2

 

65.2

71.1

 

71.1

 

74.0

 

74.0

84.6

 

84.6

 

 

kW

5.32

5.61

5.84

6.33

 

6.75

7.10

 

7.27

7.91

 

 

 

 

 

 

70

2400

Cap.

37.5

 

31.9

43.8

 

40.2

48.2

 

43.9

57.7

 

50.5

65.6

 

65.6

71.8

 

71.8

 

74.7

 

74.7

85.4

 

85.4

 

kW

5.13

5.38

5.57

5.97

 

6.32

6.61

 

6.74

7.25

 

 

 

 

 

 

 

3000

Cap.

37.6

 

32.0

43.9

 

40.3

48.3

 

44.0

57.8

 

50.7

66.0

 

66.0

72.1

 

72.1

 

75.0

 

75.0

86.0

 

86.0

 

 

kW

5.03

5.25

5.41

5.76

 

6.08

6.32

 

6.44

6.89

 

 

 

 

 

 

 

1800

Cap.

36.8

 

31.3

43.1

 

39.6

47.9

 

43.7

57.1

 

50.1

64.8

 

64.8

70.5

 

70.5

 

73.4

 

73.4

83.6

 

83.6

 

 

kW

5.75

6.09

6.34

6.88

 

7.35

7.72

 

7.90

8.58

 

 

 

 

 

 

80

2400

Cap.

37.0

 

31.4

43.4

 

39.8

48.0

 

43.8

57.4

 

50.3

65.1

 

65.1

71.1

 

71.1

 

73.9

 

73.9

84.5

 

84.5

 

kW

5.55

5.83

6.04

6.49

 

6.87

7.18

 

7.33

7.89

 

 

 

 

 

 

 

3000

Cap.

37.1

 

31.5

43.5

 

39.9

48.1

 

43.9

57.5

 

50.4

65.3

 

65.3

71.5

 

71.5

 

74.4

 

74.4

85.0

 

85.0

 

 

kW

5.44

5.68

5.87

6.26

 

6.60

6.88

 

7.01

7.49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

548F090

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

Cfm

 

 

 

 

 

 

 

 

Air Temperature Entering Outdoor Coil (F)

 

 

 

 

 

 

 

 

 

Air

(Standard

 

0

 

10

 

17

 

30

 

 

 

40

47

 

 

 

50

 

60

(F db)

Air)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

Cap.

36.6

 

31.2

44.0

 

40.4

49.8

 

45.4

61.4

 

53.8

70.4

 

70.4

77.4

 

77.4

 

80.6

 

80.6

91.8

 

91.8

 

 

kW

5.24

5.64

5.94

6.58

 

7.08

7.50

 

7.68

8.32

 

 

 

 

 

 

55

2600

Cap.

37.6

 

32.0

45.2

 

41.4

51.2

 

46.6

63.0

 

55.2

72.4

 

72.4

79.6

 

79.6

 

83.0

 

83.0

92.4

 

92.4

 

kW

5.18

5.56

5.82

6.40

 

6.84

7.20

 

7.36

7.78

 

 

 

 

 

 

 

3200

Cap.

38.2

 

32.4

45.8

 

42.0

51.8

 

47.2

63.8

 

55.8

73.6

 

73.6

81.0

 

81.0

 

83.8

 

83.8

91.2

 

91.2

 

 

kW

5.16

5.50

5.74

6.28

 

6.70

7.02

 

7.12

7.40

 

 

 

 

 

 

 

2000

Cap.

32.4

 

27.6

40.4

 

37.2

46.0

 

41.8

57.8

 

50.6

66.8

 

66.8

73.6

 

73.6

 

76.6

 

76.6

87.8

 

87.8

 

 

kW

5.42

5.90

6.22

6.92

 

7.48

7.94

 

8.16

8.90

 

 

 

 

 

 

70

2600

Cap.

33.4

 

28.4

41.8

 

38.2

47.4

 

43.2

59.6

 

52.2

68.8

 

68.8

75.8

 

75.8

 

79.0

 

79.0

90.4

 

90.4

 

kW

5.38

5.82

6.12

6.76

 

7.28

7.68

 

7.86

8.48

 

 

 

 

 

 

 

3200

Cap.

34.2

 

29.0

42.2

 

38.6

48.4

 

44.0

60.6

 

53.0

70.0

 

70.0

77.2

 

77.2

 

80.6

 

80.6

91.0

 

91.0

 

 

kW

5.36

5.76

6.06

6.66

 

7.14

7.50

 

7.68

8.16

 

 

 

 

 

 

 

2000

Cap.

29.2

 

24.8

37.4

 

34.4

43.4

 

39.6

54.8

 

48.0

64.0

 

64.0

70.8

 

70.8

 

73.8

 

73.8

84.8

 

84.8

 

 

kW

5.52

6.02

6.40

7.12

 

7.72

8.22

 

8.44

9.24

 

 

 

 

 

 

80

2600

Cap.

30.2

 

25.8

38.8

 

35.6

44.6

 

40.6

56.8

 

49.8

66.2

 

66.2

73.2

 

73.2

 

76.4

 

76.4

87.8

 

87.8

 

kW

5.48

5.96

6.30

6.98

 

7.54

7.98

 

8.18

8.88

 

 

 

 

 

 

 

3200

Cap.

31.0

 

26.4

39.6

 

36.4

45.4

 

41.4

58.0

 

50.8

67.4

 

67.4

74.6

 

74.6

 

78.0

 

78.0

89.0

 

89.0

 

 

kW

5.46

5.92

6.24

6.90

 

7.42

7.82

 

8.00

8.58

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cap. — Heating Capacity (1000 Btuh) (includes indoor-fan motor heat)

 

1.

 

 

indicates integrated ratings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

db

dry bulb

 

 

 

 

 

 

 

 

 

 

2. Integrated capacity is maximum (instantaneous) capacity less the

kW

Total Power Input (includes compressor motor power input,

 

 

 

effect of frost on the outdoor coil and the heat required to defrost it.

 

outdoor-fan motor input, and indoor-fan motor input)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

Page 30
Image 30
Bryant 542J, 549B manual 548F036-120, PERFORMANCE DATA cont, INSTANTANEOUS AND INTEGRATED HEATING RATINGS cont, 1800