PERFORMANCE DATA (cont)

INSTANTANEOUS AND INTEGRATED HEATING RATINGS (cont)

 

 

 

549B060 (5 Tons)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

Cfm

 

 

 

 

 

 

Temperature Air Entering Outdoor Coil (F db at 70% rh)

 

 

 

 

 

 

 

 

Air

(Standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–20

–10

 

0

10

17

30

40

47

50

60

 

 

 

(F db)

Air)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

Cap.

19.4

17.8

24.8

22.8

29.7

 

27.3

34.7

31.8

38.5

35.1

46.8

41.0

53.9

53.9

59.5

59.5

62.1

62.1

71.9

71.9

 

 

 

 

kW

3.28

3.53

3.67

3.77

3.85

4.04

4.21

4.36

4.43

4.73

 

 

 

 

 

 

 

 

55

2000

Cap.

20.7

19.0

25.9

23.8

30.6

 

28.1

35.6

32.6

39.5

36.0

48.0

42.1

55.4

55.4

61.1

61.1

63.8

63.8

73.3

73.3

 

 

 

kW

3.48

3.68

3.77

3.84

3.90

4.04

4.18

4.30

4.37

4.60

 

 

 

 

 

 

 

 

 

2500

Cap.

21.7

20.0

26.8

24.7

31.4

 

28.9

36.4

33.4

40.4

36.8

49.0

42.9

56.5

56.5

62.2

62.2

65.0

65.0

72.1

72.1

 

 

 

 

kW

3.69

3.85

3.92

3.98

4.03

4.15

4.28

4.40

4.46

4.61

 

 

 

 

 

 

 

 

 

1500

Cap.

14.5

13.3

21.8

20.0

28.2

 

26.0

34.0

31.2

37.8

34.5

45.7

40.1

52.4

52.4

57.7

57.7

60.2

60.2

69.5

69.5

 

 

 

 

kW

3.20

3.71

4.07

4.30

4.42

4.64

4.83

5.00

5.08

5.40

 

 

 

 

 

 

 

 

70

2000

Cap.

15.9

14.7

23.3

21.4

29.5

 

27.1

34.9

32.1

38.7

35.3

46.8

41.0

53.7

53.7

59.3

59.3

61.8

61.8

71.5

71.5

 

 

 

kW

3.44

3.91

4.20

4.36

4.43

4.59

4.74

4.87

4.94

5.21

 

 

 

 

 

 

 

 

 

2500

Cap.

17.2

15.8

24.5

22.5

30.5

 

28.1

35.8

32.9

39.6

36.1

47.8

41.9

54.8

54.8

60.4

60.4

63.1

63.1

72.4

72.4

 

120-549B036

 

 

kW

3.67

4.11

4.35

4.47

4.53

4.66

4.79

4.91

4.97

5.21

 

 

 

 

 

 

 

1500

Cap.

9.9

9.1

18.3

16.8

25.9

 

23.8

32.8

30.1

37.0

33.8

45.1

39.5

51.6

51.6

56.7

56.7

59.1

59.1

68.1

68.1

 

 

 

 

 

 

 

 

 

kW

3.04

3.66

4.20

4.60

4.80

5.10

5.32

5.49

5.58

5.92

 

 

 

 

 

 

 

 

80

2000

Cap.

11.2

10.3

20.0

18.4

27.5

 

25.3

34.2

31.4

38.2

34.8

46.1

40.4

52.8

52.8

58.1

58.1

60.6

60.6

70.0

70.0

 

 

 

kW

3.27

3.89

4.38

4.69

4.83

5.02

5.18

5.32

5.38

5.66

 

 

 

 

 

 

 

 

 

2500

Cap.

12.4

11.4

21.3

19.6

28.8

 

26.5

35.1

32.3

39.1

35.6

47.1

41.2

53.9

53.9

59.3

59.3

61.8

61.8

71.4

71.4

 

 

 

 

kW

3.50

4.12

4.56

4.81

4.92

5.07

5.20

5.32

5.38

5.65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

549B072 (6 Tons)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

Cfm

 

 

 

 

 

 

Temperature Air Entering Outdoor Coil (F db at 70% rh)

 

 

 

 

 

 

 

 

Air

(Standard

–20

–10

 

0

10

17

30

40

47

50

60

 

 

 

(F db)

Air)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

Cap.

16.5

15.2

20.8

19.1

26.4

 

22.4

33.6

30.8

41.0

37.6

51.3

44.9

61.9

61.9

69.5

69.5

78.0

78.0

77.9

77.9

 

 

 

 

kW

3.50

3.63

3.79

4.01

4.18

4.57

4.94

5.22

5.57

5.55

 

 

 

 

 

 

 

 

 

2100

Cap.

16.9

15.5

21.2

19.5

27.2

 

23.1

34.9

32.0

41.8

38.3

52.2

45.8

63.2

63.2

69.6

69.6

75.7

75.7

76.5

76.5

 

 

 

55

kW

3.56

3.68

3.84

4.04

4.18

4.54

4.86

5.07

5.30

5.32

 

 

 

 

 

 

 

2400

Cap.

17.2

15.9

21.8

20.0

28.0

 

23.8

35.6

32.6

43.1

39.5

53.8

47.2

64.1

64.1

69.0

69.0

74.8

74.8

74.3

74.3

 

 

 

 

 

 

 

 

 

kW

3.64

3.75

3.89

4.08

4.21

4.54

4.82

4.97

5.18

5.15

 

 

 

 

 

 

 

 

 

3000

Cap.

18

16.5

23.0

21.1

29.4

 

25.0

37.4

34.4

45.2

41.4

56.6

49.6

63.2

63.2

65.5

65.5

69.8

69.8

70.6

70.6

 

 

 

 

kW

3.79

3.90

4.03

4.19

4.32

4.61

4.77

4.84

4.98

4.99

 

 

 

 

 

 

 

 

 

1800

Cap.

15.2

14.0

18.2

16.7

24.1

 

20.5

31.1

28.5

38.0

34.8

47.7

41.8

58.4

58.4

67.1

67.1

78.0

78.0

77.9

77.9

 

 

 

 

kW

3.97

4.12

4.33

4.57

4.75

5.19

5.59

5.94

6.43

6.41

 

 

 

 

 

 

 

 

 

2100

Cap.

15.6

14.4

18.6

17.1

24.8

 

21.1

32.0

29.4

39.1

35.9

49.1

43.1

59.7

59.7

68.5

68.5

77.3

77.3

76.7

76.7

 

 

 

70

kW

4.04

4.18

4.37

4.59

4.76

5.15

5.51

5.81

6.17

6.13

 

 

 

 

 

 

 

2400

Cap.

16.1

14.8

19.0

17.5

25.9

 

22.0

32.7

30.0

39.9

36.6

51.1

44.7

61.3

61.3

69.0

69.0

75.6

75.6

76.3

76.3

 

 

 

 

 

 

 

 

 

kW

4.11

4.24

4.43

4.63

4.79

5.17

5.48

5.73

5.97

5.99

 

 

 

 

 

 

 

 

 

3000

Cap.

16.8

15.5

19.7

18.1

26.7

 

22.7

34.3

31.5

41.8

38.3

53.5

46.8

63.7

63.7

68.3

68.3

73.0

73.0

73.8

73.8

 

 

 

 

kW

4.28

4.39

4.56

4.75

4.89

5.22

5.49

5.63

5.80

5.82

 

 

 

 

 

 

 

 

 

1800

Cap.

13.6

12.5

17.1

15.7

21.7

 

18.4

29.2

26.8

36.5

33.4

45.6

40.0

55.3

55.3

64.2

64.2

77.2

77.2

76.9

76.9

 

 

 

 

kW

4.20

4.46

4.67

4.95

5.16

5.62

6.02

6.40

7.00

6.98

 

 

 

 

 

 

 

 

 

2100

Cap.

14.1

13.0

17.6

16.2

22.6

 

19.2

30.1

27.6

37.1

34.0

46.9

41.1

57.0

57.0

66.4

66.4

76.3

76.3

77.2

77.2

 

 

 

80

kW

4.28

4.52

4.72

4.98

5.16

5.58

5.95

6.30

6.71

6.74

 

 

 

 

 

 

 

2400

Cap.

14.5

13.4

18.0

16.6

23.1

 

19.6

31.2

28.7

37.9

32.7

48.5

42.5

58.7

58.7

67.7

67.7

76.3

76.3

75.9

75.9

 

 

 

 

 

 

 

 

 

kW

4.37

4.59

4.77

5.03

34.7

5.59

5.93

6.23

6.57

6.54

 

 

 

 

 

 

 

 

 

3000

Cap.

15.4

14.1

18.8

17.3

24.1

 

20.5

32.2

29.6

39.6

36.3

50.4

44.2

61.6

61.6

68.9

68.9

74.3

74.3

74.5

74.5

 

 

 

 

kW

4.54

4.74

4.91

5.14

5.29

5.64

5.95

6.17

6.37

6.36

 

 

 

 

 

LEGEND

Cap. — Heating Capacity (1000 Btuh) (includes indoor-fan motor heat) kW — Total Power Input (includes compressor motor power input,

outdoor-fan motor input, and indoor-fan motor input) rh — Relative Humidity

NOTES:

1. indicates integrated ratings.

2.Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.

78

Page 78
Image 78
Bryant 542J, 548F manual 549B060 5 Tons, 549B072 6 Tons, 2100 Cap

549B, 548F, 542J specifications

Bryant 542J is a high-efficiency gas furnace that stands out for its reliability and advanced heating technologies. Designed to deliver consistent warmth and comfort in residential settings, it combines innovative engineering with energy-efficient features.

One of the key characteristics of the Bryant 542J is its two-stage heating capability. This means that the furnace can adjust its heat output according to the heating demands of your home. During milder weather, it operates at a lower stage, consuming less energy while still maintaining a comfortable environment. When the temperatures drop, the furnace shifts to its higher capacity, providing the necessary warmth efficiently. This not only enhances comfort but also contributes to lower energy bills.

In addition to its two-stage operation, the Bryant 542J also incorporates a variable-speed blower motor. This technology allows the furnace to adjust the airflow depending on the heating requirements, ensuring an even distribution of warm air throughout the home. The variable-speed blower also operates more quietly than conventional fixed-speed motors, creating a serene indoor environment.

Energy efficiency is a hallmark of the Bryant 542J, boasting an Annual Fuel Utilization Efficiency (AFUE) rating of up to 96.5%. This impressive rating means that a significant portion of the energy consumed is effectively converted into usable heat, resulting in substantial savings on heating costs over time. Furthermore, the furnace is equipped with a sealed combustion system that draws air from outside the home, minimizing energy waste and improving indoor air quality.

Diagnostic features are another highlight of the Bryant 542J, which come equipped with SmartEvap technology. This allows the unit to self-diagnose potential issues, providing homeowners with peace of mind and simplifying maintenance procedures.

Durability is also a key feature of the Bryant 542J. It is constructed with high-quality materials designed to withstand harsh winter conditions, ensuring a long lifespan and reliable performance. Its compact design also allows for flexible installation, making it suitable for various residential layouts.

In summary, the Bryant 542J is more than just a gas furnace; it is a sophisticated heating solution that combines efficiency, comfort, and reliability. With features such as two-stage heating, a variable-speed blower, high AFUE ratings, and advanced diagnostics, it is an excellent choice for homeowners seeking an efficient and effective heating system.