120-548F036

TYPICAL WIRING SCHEMATIC (cont)

7 1/2 AND 8 1/2 TON UNITS ONLY

LEGEND

AHA — Adjustable Heat Anticipator

AWG — American Wire Gage

CContactor, Compressor

CAP — Capacitor

CB — Circuit Breaker

CCCooling Capacitor

CH — Crankcase Heater

CLO — Compressor Lockout COMP — Compressor Motor

DDiode

DB

Defrost Board

DFT

Defrost Thermostat

EC

Enthalpy Control

ECON

Economizer

EPS

Emergency Power Supply

 

(Nine-Volt Battery)

EQUIP

Equipment

ER

Economizer Relay

FPT

Freeze-Up Protection

 

Thermostat

FU

Fuse

GND

Ground

HC

Heater Contactor (Strip Heat)

HPS

High-Pressure Switch

HR

Heater Relay

IFC

Indoor-Fan Contactor

IFM

Indoor-Fan Motor

IFMOVL — Indoor-Fan Motor

 

Overload Switch

LPS

Low-Pressure Switch

LSM

Limit Switch (Manual Reset)

MCA

Minimum Circuit Amps

MTR

Motor

OAT

Outdoor-Air Thermostat

OFC

Outdoor-Fan Contactor

OFM

Outdoor-Fan Motor

PPlug

PL — Plug Assembly

QT — Quadruple Terminal

RRelay

 

RED

24VAC

 

ACTUATOR

BRN

24COM

 

50DK509044

GRN

GND

 

 

GRY

CL01

 

 

ORN

CL02

 

 

 

STEPPER DRIVE

50DK508232

 

 

B1

 

 

BLU

Y1

 

 

YEL

Y2

 

 

BLK

G

 

 

 

AO

 

 

 

COM

 

 

CONFIG

 

 

 

 

STATUS

-1

 

 

 

 

 

 

AD-DME1711

20 0

60

100 80

MIN POS(X)

 

 

40

 

 

 

 

 

B

 

C

ECON

 

EconoMi$er

A

30º

D

SP

800

OFF

12001400

SPCOMECHCLG

(PPM)LOCKOUT

 

 

º20

 

º 40

 

 

 

º 10

 

 

 

 

 

 

 

 

º 50

 

 

 

1000

 

 

 

 

 

 

 

50DK508234

OAT

TAN

OAT

COM

VIO

 

OAH

WHT

 

+15V

RED

 

RAT

TAN

 

COM

VIO

 

RAM

WHT

 

+15V

RED

 

CO2 +

 

RAT

 

 

CO2 (COM)

DAT VIO

COM PNK

REM POT

COM

LED

COMFIELD INSTALLED

OPTION

AIR ENTHALPY

USED FORMOUTDOOR

VIO WHT RED

RED

1

BLU

2

BLK

3 BRN 4

GRY 5 VIO 6

PNK

7 YEL 8 ORN 9

10

11

12

PL6

RAT

Return-Air Thermostat

RVS

Reversing Valve Solenoid

SAT

Supply-Air Thermostat

SW1

Switch Fully Open

SW2

Switch Fully Closed

SW3

Switch Min. Vent Position

SW4

Switch Max. Vent Position

TB

Terminal Block

TC

Thermostat-Cooling

TH

Thermostat-Heating

TRAN

Transformer

 

Field Splice

 

Marked Wire

 

Terminal (Marked)

 

Terminal (Unmarked)

 

Terminal Block

 

Splice

 

Splice (Marked)

12-PIN

 

 

WHT/YEL

FEMALE

 

 

BLK/YEL

12

8

4

 

 

 

 

1

WHT/GRY

11

7

3

 

 

 

 

 

3-PIN

2

BLK/GRY

10

6

2

MOLEX

 

 

 

 

 

BRN

9

5

1

 

3

 

NOT USED

MOLEX

 

 

CONNECTOR

CONNECTOR CABLE

548F090-120

Factory Wiring

Field Control Wiring

Field Power Wiring

Accessory or

Optional Wiring

To indicate common

potential only. Not to

represent wiring.

66

Page 66
Image 66
Bryant 542J, 548F, 549B manual Typical Wiring Schematic, Outdoor-Fan Motor

549B, 548F, 542J specifications

Bryant 542J is a high-efficiency gas furnace that stands out for its reliability and advanced heating technologies. Designed to deliver consistent warmth and comfort in residential settings, it combines innovative engineering with energy-efficient features.

One of the key characteristics of the Bryant 542J is its two-stage heating capability. This means that the furnace can adjust its heat output according to the heating demands of your home. During milder weather, it operates at a lower stage, consuming less energy while still maintaining a comfortable environment. When the temperatures drop, the furnace shifts to its higher capacity, providing the necessary warmth efficiently. This not only enhances comfort but also contributes to lower energy bills.

In addition to its two-stage operation, the Bryant 542J also incorporates a variable-speed blower motor. This technology allows the furnace to adjust the airflow depending on the heating requirements, ensuring an even distribution of warm air throughout the home. The variable-speed blower also operates more quietly than conventional fixed-speed motors, creating a serene indoor environment.

Energy efficiency is a hallmark of the Bryant 542J, boasting an Annual Fuel Utilization Efficiency (AFUE) rating of up to 96.5%. This impressive rating means that a significant portion of the energy consumed is effectively converted into usable heat, resulting in substantial savings on heating costs over time. Furthermore, the furnace is equipped with a sealed combustion system that draws air from outside the home, minimizing energy waste and improving indoor air quality.

Diagnostic features are another highlight of the Bryant 542J, which come equipped with SmartEvap technology. This allows the unit to self-diagnose potential issues, providing homeowners with peace of mind and simplifying maintenance procedures.

Durability is also a key feature of the Bryant 542J. It is constructed with high-quality materials designed to withstand harsh winter conditions, ensuring a long lifespan and reliable performance. Its compact design also allows for flexible installation, making it suitable for various residential layouts.

In summary, the Bryant 542J is more than just a gas furnace; it is a sophisticated heating solution that combines efficiency, comfort, and reliability. With features such as two-stage heating, a variable-speed blower, high AFUE ratings, and advanced diagnostics, it is an excellent choice for homeowners seeking an efficient and effective heating system.