PERFORMANCE DATA (cont)

FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS (cont)

548F120 (10 TONS)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

0.2

 

 

 

 

0.4

 

 

 

0.6

 

 

 

 

 

 

0.8

 

 

1.0

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Watts

 

Rpm

Bhp

Watts

 

Rpm

Bhp

 

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

3000

 

484

 

0.55

 

562

 

560

0.70

677

 

631

0.87

 

810

690

 

1.03

940

747

1.20

 

1081

3100

 

495

 

0.61

 

607

 

570

0.76

723

 

638

0.92

 

851

699

 

1.10

998

755

1.27

 

1140

3200

 

505

 

0.66

 

646

 

579

0.81

763

 

646

0.98

 

899

708

 

1.16

1047

761

1.34

 

1199

3300

 

516

 

0.72

 

692

 

589

0.87

810

 

655

1.05

 

956

717

 

1.23

1106

767

1.40

 

1250

3400

 

527

 

0.78

 

739

 

599

0.93

859

 

664

1.11

 

1006

724

 

1.30

1165

775

1.48

 

1318

3500

 

537

 

0.85

 

795

 

609

0.99

907

 

672

1.18

 

1064

731

 

1.36

1216

784

1.56

 

1387

3600

 

548

 

0.92

 

851

 

619

1.05

956

 

680

1.24

 

1114

738

 

1.43

1275

794

1.64

 

1456

3700

 

560

 

1.00

 

916

 

629

1.12

1014

 

688

1.31

 

1173

747

 

1.51

1344

802

1.73

 

1534

3800

 

571

 

1.08

 

981

 

639

1.19

1072

 

698

1.39

 

1241

756

 

1.60

1422

810

1.81

 

1604

3900

 

582

 

1.16

 

1047

 

649

1.27

1140

 

708

1.47

 

1310

764

 

1.69

1499

816

1.89

 

1674

4000

 

593

 

1.25

 

1123

 

659

1.35

1207

 

717

1.56

 

1387

773

 

1.78

1578

823

1.98

 

1753

4100

 

605

 

1.35

 

1207

 

670

1.44

1284

 

727

1.65

 

1465

781

 

1.86

1648

832

2.08

 

1840

4200

 

616

 

1.45

 

1292

 

680

1.53

1361

 

737

1.74

 

1543

789

 

1.95

1726

841

2.18

 

1927

4300

 

628

 

1.56

 

1387

 

690

1.63

1447

 

747

1.83

 

1621

798

 

2.05

1814

849

2.30

 

2032

4400

 

639

 

1.67

 

1482

 

701

1.73

1534

 

757

1.92

 

1700

807

 

2.16

1910

858

2.41

 

2177

4500

 

651

 

1.78

 

1578

 

712

1.84

1630

 

767

2.02

 

1788

817

 

2.27

2006

866

2.51

 

2265

4600

 

662

 

1.91

 

1691

 

722

1.95

1726

 

777

2.13

 

1884

827

 

2.38

2102

874

2.62

 

2362

4700

 

674

 

2.03

 

1796

 

733

2.07

1831

 

787

2.24

 

1980

836

 

2.50

2256

882

2.73

 

2460

4800

 

686

 

2.17

 

1919

 

744

2.20

1945

 

797

2.36

 

2084

846

 

2.62

2362

891

2.85

 

2569

4900

 

698

 

2.31

 

2041

 

755

2.33

2058

 

808

2.48

 

2238

856

 

2.73

2460

900

2.99

 

2698

5000

 

710

 

2.45

 

2212

 

766

2.47

2230

 

818

2.61

 

2353

866

 

2.86

2578

910

3.12

 

2819

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

548F120 (10 TONS)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

1.2

 

 

 

 

1.4

 

 

 

1.6

 

 

 

 

 

 

1.8

 

 

2.0

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Watts

 

Rpm

Bhp

Watts

 

Rpm

Bhp

 

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

3000

 

800

 

1.38

 

1233

 

850

1.52

1353

 

879

1.38

 

1233

925

 

1.81

1604

964

1.92

 

1761

3100

 

805

 

1.44

 

1284

 

857

1.63

1447

 

896

1.66

 

1473

935

 

1.93

1709

975

1.98

 

1811

3200

 

812

 

1.51

 

1344

 

862

1.71

1517

 

908

1.85

 

1639

944

 

2.01

1836

984

2.09

 

1903

3300

 

819

 

1.59

 

1413

 

867

1.78

1578

 

915

1.98

 

1753

952

 

2.11

1920

993

2.22

 

2014

3400

 

827

 

1.67

 

1482

 

873

1.85

1639

 

920

2.07

 

1831

963

 

2.21

2005

1001

2.31

 

2091

3500

 

833

 

1.75

 

1552

 

880

1.94

1718

 

926

2.15

 

1901

970

 

2.41

2134

1007

2.46

 

2221

3600

 

840

 

1.83

 

1621

 

888

2.04

1805

 

931

2.23

 

1971

976

 

2.47

2230

1017

2.62

 

2362

3700

 

847

 

1.92

 

1700

 

895

2.13

1884

 

938

2.33

 

2108

981

 

2.56

2309

1024

2.77

 

2496

3800

 

856

 

2.02

 

1788

 

901

2.23

1971

 

945

2.44

 

2203

986

 

2.65

2389

1029

2.89

 

2605

3900

 

865

 

2.12

 

1875

 

908

2.32

2050

 

953

2.55

 

2300

993

 

2.75

2478

1034

3.00

 

2707

4000

 

875

 

2.22

 

1962

 

915

2.42

2186

 

960

2.65

 

2389

1000

 

2.87

2587

1039

3.10

 

2800

4100

 

883

 

2.32

 

2050

 

924

2.54

2291

 

966

2.76

 

2487

1008

 

2.99

2698

1046

3.21

 

2904

4200

 

889

 

2.41

 

2177

 

934

2.65

2389

 

972

2.87

 

2587

1015

 

3.12

2819

1053

3.34

 

3029

4300

 

896

 

2.51

 

2265

 

943

2.77

2406

 

980

2.99

 

2698

1021

 

3.23

2923

1061

3.48

 

3166

4400

 

903

 

2.62

 

2362

 

951

2.89

2603

 

990

3.12

 

2819

1028

 

3.36

3049

1068

3.61

 

3241

4500

 

912

 

2.74

 

2469

 

958

3.00

2707

 

999

3.26

 

2982

1035

 

3.51

3161

1074

3.74

 

3346

4600

 

921

 

2.87

 

2587

 

965

3.11

2810

 

1008

3.39

 

3078

1041

 

3.68

3295

1081

3.90

 

3450

4700

 

930

 

3.00

 

2707

 

972

3.23

2923

 

1017

3.45

 

3224

1048

 

3.80

3436

1088

4.13

 

3552

4800

 

938

 

3.14

 

2838

 

980

3.37

3058

 

1025

3.55

 

3362

1055

 

3.85

3584

1095

4.30

 

3653

4900

 

946

 

3.27

 

2962

 

990

3.51

3149

 

1034

3.71

 

3505

1062

 

3.98

3741

1101

4.45

 

3753

5000

 

954

 

3.39

 

3078

 

998

3.62

3271

 

1042

3.85

 

3654

1068

 

4.08

3907

1108

4.59

 

3851

 

 

LEGEND

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

Bhp — Brake Horsepower Input to Fan

 

 

 

 

1. Boldface indicates field-supplied drive is required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watts — Input Watts to Motor

 

 

 

 

 

 

 

2.

 

 

indicates high-static motor and drive are required.

*Standard motor drive range: 685 to 935 rpm. Alternate motor drive

3. Maximum usable watts input is 2120 with standard motor, 2615 with

alternate motor,

and

4400

for the high-static

motor. Maximum

range: 835

to 1085

rpm. High static

motor

drive

range: 830

to

continuous

bhp

is 2.40 with

standard

motor, 2.90 with

alternate

1130 rpm. All other rpms require field-supplied drive.

 

 

 

 

 

 

motor and 5.25 with high-static motor.

 

 

 

 

Refer to this page for general Fan Performance notes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL NOTES FOR FAN PERFORMANCE TABLES

 

 

 

 

 

 

1. Extensive motor and electrical testing on these units ensures that

2.

Values include losses for filters, unit casing, and wet coils. See

the full range of the motor can be utilized with confidence. Using

 

page 52 for accessory/FIOP (factory-installed option) static pres-

your fan motors up to the wattage ratings shown will not result in

 

sure information.

 

 

 

 

 

 

nuisance tripping or premature motor failure. Unit warranty will not

3. Use of a field-supplied motor may affect wire sizing. Contact your

be affected. For additional information on motor performance, refer

 

Bryant representative for details.

 

 

 

 

to Indoor-Fan Motor Performance table on page 55.

 

4.

Interpolation is permissible. Do not extrapolate. (Belt drive units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

only.)

 

 

 

 

 

 

 

 

 

548F036-120

51

Page 51
Image 51
Bryant 542J, 548F, 549B manual General Notes for FAN Performance Tables

549B, 548F, 542J specifications

Bryant 542J is a high-efficiency gas furnace that stands out for its reliability and advanced heating technologies. Designed to deliver consistent warmth and comfort in residential settings, it combines innovative engineering with energy-efficient features.

One of the key characteristics of the Bryant 542J is its two-stage heating capability. This means that the furnace can adjust its heat output according to the heating demands of your home. During milder weather, it operates at a lower stage, consuming less energy while still maintaining a comfortable environment. When the temperatures drop, the furnace shifts to its higher capacity, providing the necessary warmth efficiently. This not only enhances comfort but also contributes to lower energy bills.

In addition to its two-stage operation, the Bryant 542J also incorporates a variable-speed blower motor. This technology allows the furnace to adjust the airflow depending on the heating requirements, ensuring an even distribution of warm air throughout the home. The variable-speed blower also operates more quietly than conventional fixed-speed motors, creating a serene indoor environment.

Energy efficiency is a hallmark of the Bryant 542J, boasting an Annual Fuel Utilization Efficiency (AFUE) rating of up to 96.5%. This impressive rating means that a significant portion of the energy consumed is effectively converted into usable heat, resulting in substantial savings on heating costs over time. Furthermore, the furnace is equipped with a sealed combustion system that draws air from outside the home, minimizing energy waste and improving indoor air quality.

Diagnostic features are another highlight of the Bryant 542J, which come equipped with SmartEvap technology. This allows the unit to self-diagnose potential issues, providing homeowners with peace of mind and simplifying maintenance procedures.

Durability is also a key feature of the Bryant 542J. It is constructed with high-quality materials designed to withstand harsh winter conditions, ensuring a long lifespan and reliable performance. Its compact design also allows for flexible installation, making it suitable for various residential layouts.

In summary, the Bryant 542J is more than just a gas furnace; it is a sophisticated heating solution that combines efficiency, comfort, and reliability. With features such as two-stage heating, a variable-speed blower, high AFUE ratings, and advanced diagnostics, it is an excellent choice for homeowners seeking an efficient and effective heating system.