Bryant Performance Data, 551A155-180, Cooling Capacities, Bypass, Entering Air Dry-Bulb Temp F

Models: 551A 551B 558F

1 170
Download 170 pages 34.1 Kb
Page 158
Image 158

PERFORMANCE DATA

COOLING CAPACITIES

551A155 (13 TONS)

Temp (F)

 

 

 

 

 

Evaporator Air Quantity — Cfm/BF

 

 

 

 

 

 

 

3600/0.03

 

 

4375/0.04

 

 

5000/0.05045

 

 

5625/0.06

 

 

6250/0.07

 

Air Entering

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator Air — Ewb (F)

 

 

 

 

 

 

 

 

(Edb

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

67

72

62

67

72

62

 

67

 

72

62

67

72

62

 

67

72

 

 

TC

134

145

153

137

148

156

141

 

149

 

156

144

151

157

147

 

152

157

75

 

SHC

111

93

72

124

103

77

130

 

109

 

77

134

114

79

137

 

119

79

 

 

kW

7.9

8.1

8.2

8.0

8.2

8.3

8.1

 

8.2

 

8.3

8.1

8.2

8.3

8.2

 

8.2

8.3

85

 

TC

130

140

147

133

142

149

136

 

144

 

149

139

145

150

141

 

146

150

 

SHC

109

90

68

120

97

72

127

 

106

 

73

130

110

76

132

 

112

76

 

 

kW

8.9

9.1

9.2

8.9

9.1

9.2

9.0

 

9.1

 

9.2

9.1

9.2

9.2

9.1

 

9.2

9.2

95

 

TC

125

134

141

128

136

142

131

 

138

 

142

133

138

142

136

 

139

142

 

SHC

106

87

66

117

94

69

122

 

99

 

71

124

104

72

127

 

108

73

 

 

kW

9.9

10.1

10.2

10.0

10.1

10.2

10.1

 

10.2

 

10.2

10.1

10.2

10.2

10.2

 

10.2

10.2

105

 

TC

120

129

134

123

130

134

126

 

131

 

134

128

132

135

129

 

132

135

 

SHC

104

85

63

114

91

67

117

 

95

 

67

119

100

68

120

 

105

70

 

 

kW

11.1

11.2

11.3

11.1

11.3

11.3

11.2

 

11.3

 

11.4

11.2

11.3

11.4

11.3

 

11.3

11.4

115

 

TC

114

122

127

117

123

127

120

 

124

 

127

121

124

127

122

 

125

127

 

SHC

100

81

60

109

87

62

111

 

93

 

64

113

95

66

114

 

98

66

 

 

kW

12.3

12.5

12.6

12.4

12.5

12.6

12.4

 

12.5

 

12.6

12.5

12.5

12.6

12.5

 

12.5

12.6

117

 

TC

108

115

118

122

124

127

123

 

124

 

126

123

124

127

124

 

125

127

 

SHC

98

78

57

89

77

64

91

 

79

 

64

91

80

66

92

 

81

66

 

 

kW

13.6

13.8

13.9

12.6

12.7

12.7

12.6

 

12.7

 

12.7

12.7

12.7

12.7

12.7

 

12.7

12.7

120

 

TC

112

119

123

114

119

123

116

 

120

 

123

117

120

123

118

 

120

123

 

SHC

100

80

59

106

85

61

108

 

89

 

62

109

92

64

110

 

96

64

 

 

kW

12.9

13.1

13.2

13.0

13.1

13.2

13.1

 

13.2

 

13.2

13.1

13.2

13.2

13.1

 

13.2

13.2

125

 

TC

109

115

118

111

115

119

113

 

116

 

119

114

116

119

115

 

116

119

 

SHC

98

79

57

103

84

59

105

 

88

 

61

106

90

64

107

 

93

63

 

 

kW

13.6

13.8

13.9

13.7

13.8

13.9

13.7

 

13.8

 

13.9

13.8

13.8

13.9

13.8

 

13.8

13.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

551A180 (15 TONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

Evaporator Air Quantity — Cfm/BF

 

 

 

 

 

 

Air Entering

 

4500/0.02

 

 

5250/0.03

 

 

6000/0.04

 

 

 

6750/0.04

 

 

7500/0.05

 

Condenser

 

 

 

 

 

 

Evaporator Air — Ewb (F)

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

67

72

62

67

72

62

 

67

 

72

62

67

72

62

 

67

72

 

 

 

 

 

 

75

 

TC

181

196

213

186

201

217

189

 

204

 

219

194

206

220

198

 

208

223

 

SHC

147

124

99

160

133

105

173

 

143

 

113

181

153

120

186

 

163

125

 

 

kW

11.2

11.6

12.0

11.3

11.7

12.1

11.4

 

11.8

 

12.1

11.6

11.9

12.2

11.7

 

11.9

12.2

85

 

TC

175

190

205

180

194

209

183

 

198

 

212

188

200

213

192

 

202

214

 

SHC

145

121

97

157

130

102

168

 

139

 

106

175

148

115

180

 

157

119

 

 

kW

12.3

12.7

13.1

12.5

12.8

13.2

12.6

 

12.9

 

13.3

12.7

13.0

13.3

12.8

 

13.1

13.4

95

 

TC

168

182

197

172

187

201

176

 

190

 

203

181

192

205

185

 

194

206

 

SHC

142

118

93

154

127

98

164

 

136

 

102

170

144

108

174

 

153

113

 

 

kW

13.5

13.9

14.3

13.6

14.0

14.4

13.8

 

14.1

 

14.5

13.9

14.2

14.6

14.0

 

14.3

14.6

105

 

TC

161

174

188

165

178

191

169

 

181

 

193

173

182

194

177

 

184

194

 

SHC

138

115

91

150

124

95

158

 

132

 

98

162

140

103

166

 

148

107

 

 

kW

14.8

15.2

15.6

14.9

15.3

15.7

15.1

 

15.4

 

15.7

15.2

15.5

15.8

15.3

 

15.5

15.8

115

 

TC

152

165

179

157

168

180

161

 

171

 

181

166

172

183

169

 

174

183

 

SHC

134

111

87

145

120

91

151

 

128

 

94

155

136

98

158

 

142

101

 

 

kW

16.1

16.5

16.9

16.2

16.6

17.0

16.4

 

16.7

 

17.0

16.6

16.8

17.1

16.7

 

16.9

17.1

120

 

TC

148

161

153

157

 

 

 

 

SHC

132

110

142

147

 

 

 

 

 

kW

16.8

17.2

16.9

17.1

 

 

 

125

 

TC

 

 

 

 

SHC

 

 

 

 

 

kW

 

 

 

551A155-180

LEGEND

BF — Bypass Factor Edb — Entering Dry-Bulb Ewb — Entering Wet-Bulb

kW — Compressor Motor Power Input ldb — Leaving Dry-Bulb

lwb — Leaving Wet-Bulb

SHC — Sensible Heat Capacity (1000 Btuh) Gross TC — Total Capacity (1000 Btuh) Gross

NOTES:

1.Direct interpolation is permissible. Do not extrapolate.

2.The following formulas may be used:

tldb = tedb

sensible capacity (Btuh)

1.10 x cfm

3.The SHC is based on 80 F edb temperature of air entering evaporator coil. Below 80 F edb, subtract (corr factor x cfm) from SHC.

Above 80 F edb, add (corr factor x cfm) to SHC.

BYPASS

 

ENTERING AIR DRY-BULB TEMP (F)

79

78

77

 

76

75

 

under 75

FACTOR

 

 

81

82

83

 

84

85

 

over 85

(BF)

 

 

 

 

 

 

Correction Factor

 

.05

1.04

2.07

3.11

 

4.14

5.18

 

Use formula

.10

.98

1.96

2.94

 

3.92

4.90

 

.20

.87

1.74

2.62

 

3.49

4.36

 

shown below.

.30

.76

1.53

2.29

 

3.05

3.82

 

 

Interpolation is permissible.

Correction Factor = 1.10 x (1 – BF) x (edb – 80).

tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving evapo- rator coil (hlwb)

h

= h

 

total capacity (Btuh)

lwb

 

ewb

 

4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil

158

Page 158
Image 158
Bryant 558F, 551B manual Performance Data, 551A155-180, Cooling Capacities, Bypass, Entering Air Dry-Bulb Temp F, Factor