558F036-150

PERFORMANCE DATA (cont)

FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS (cont)

558F102 (81/2 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

0.2

 

 

 

0.4

 

 

0.6

 

 

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

2550

 

550

 

0.69

669

627

 

0.94

867

692

1.17

 

 

1056

754

1.45

1292

812

1.74

1543

2660

 

557

 

0.72

692

634

 

0.97

891

698

1.21

 

 

1089

759

1.49

1327

816

1.79

1587

2700

 

573

 

0.79

747

648

 

1.05

956

711

1.29

 

 

1156

770

1.58

1404

827

1.88

1665

2800

 

588

 

0.86

803

662

 

1.13

1022

723

1.38

 

 

1233

782

1.66

1473

837

1.98

1753

2900

 

604

 

0.94

867

676

 

1.21

1089

737

1.48

 

 

1318

794

1.76

1560

848

2.08

1840

3000

 

620

 

1.02

932

690

 

1.30

1165

750

1.58

 

 

1404

806

1.86

1648

849

2.18

1927

3100

 

636

 

1.11

1006

704

 

1.39

1241

764

1.69

 

 

1499

818

1.97

1744

870

2.29

2023

3200

 

652

 

1.21

1089

718

 

1.49

1327

778

1.80

 

 

1595

831

2.09

1849

882

2.40

2119

3300

 

668

 

1.31

1173

732

 

1.59

1413

793

1.92

 

 

1700

844

2.21

1954

894

2.53

2232

3400

 

684

 

1.41

1258

747

 

1.70

1508

807

2.04

 

 

1805

857

2.35

2076

907

2.66

2343

3500

 

701

 

1.53

1361

762

 

1.82

1613

821

2.16

 

 

1910

871

2.48

2188

919

2.80

2462

3600

 

717

 

1.65

1465

777

 

1.94

1718

835

2.29

 

 

2023

885

2.63

2317

932

2.95

2587

3700

 

733

 

1.77

1569

792

 

2.07

1831

849

2.42

 

 

2136

899

2.78

2445

945

3.11

2718

3750

 

742

 

1.84

1630

800

 

2.14

1892

856

2.49

 

 

2197

907

2.86

2512

952

3.20

2719

3800

 

750

 

1.90

1683

807

 

2.21

1954

863

2.56

 

 

2257

914

2.93

2571

958

3.28

2854

3900

 

767

 

2.04

1805

822

 

2.35

2076

877

2.71

 

 

2386

928

3.09

2702

972

3.45

2987

4000

 

783

 

2.18

1927

838

 

2.50

2206

891

2.86

 

 

2512

942

3.26

2839

986

3.63

3121

4100

 

800

 

2.34

2067

854

 

2.66

2343

905

3.02

 

 

2645

956

3.43

2971

1000

3.81

3251

4200

 

817

 

2.49

2197

869

 

2.82

2479

920

3.19

 

 

2783

970

3.60

3099

1015

4.00

3380

4250

 

826

 

2.58

2275

877

 

2.91

2554

928

3.28

 

 

2854

977

3.69

3165

1022

4.10

3445

 

 

 

 

 

 

 

 

 

 

 

 

 

 

558F102 (81/2 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

1.2

 

 

 

1.4

 

 

1.6

 

 

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

 

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

2550

 

864

 

1.99

1761

920

 

2.39

2110

974

2.76

 

 

2428

1005

3.04

2672

1034

3.31

2910

2660

 

868

 

2.04

1805

921

 

2.41

2136

976

2.78

 

 

2445

1008

3.06

2691

1037

3.33

2931

2700

 

878

 

2.16

1910

928

 

2.45

2162

983

2.88

 

 

2529

1015

3.17

2788

1044

3.45

3036

2800

 

889

 

2.29

2023

937

 

2.57

2266

986

2.91

 

 

2554

1018

3.20

2817

1047

3.49

3068

2900

 

900

 

2.41

2128

947

 

2.70

2377

993

3.01

 

 

2637

1025

3.31

2914

1055

3.61

3174

3000

 

910

 

2.52

2223

958

 

2.85

2504

1002

3.15

 

 

2751

1034

3.47

3049

1064

3.77

3321

3100

 

920

 

2.64

2326

968

 

2.99

2620

1012

3.30

 

 

2870

1045

3.63

3195

1075

3.95

3479

3200

 

931

 

2.76

2428

979

 

3.13

2735

1023

3.47

 

 

3002

1056

3.82

3359

1087

4.16

3659

3300

 

942

 

2.89

2537

989

 

3.26

2839

1034

3.63

 

 

3121

1067

3.99

3514

3400

 

954

 

3.02

2645

1000

 

3.40

2948

1044

3.79

 

 

3237

1078

4.17

3669

3500

 

966

 

3.15

2751

1011

 

3.55

3062

1054

3.94

 

 

3340

3600

 

978

 

3.30

2870

1022

 

3.69

3165

1065

4.10

 

 

3445

3700

 

990

 

3.45

2987

1034

 

3.84

3272

 

3750

 

997

 

3.54

3055

1040

 

3.93

3333

 

3800

 

1003

 

3.62

3114

1045

 

4.01

3387

 

3900

 

1015

 

3.80

3244

1057

 

4.18

3495

 

4000

 

1028

 

3.99

3373

 

 

4100

 

1042

 

4.18

3495

 

 

4200

 

 

 

 

4250

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

Bhp

Brake Horsepower Input to Fan

 

 

 

 

 

1. Boldface indicates field-supplied drive is required.

 

 

 

Watts

Input Watts to Motor

 

 

 

 

 

 

2.

 

 

 

indicates field-supplied motor and drive are required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Motor drive range: 860 to 1080 rpm. All other rpms require field-supplied drive.

3.

Maximum continuous bhp is 3.7 and the maximum continuous watts are 3313.

4.

See page 60 for general fan performance notes.

 

58

Page 58
Image 58
Bryant 551B, 551A manual 558F036-150, PERFORMANCE DATA cont, FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont

551A, 551B, 558F specifications

The Bryant 551B and 551C are two highly efficient air conditioning units designed to provide optimal comfort in residential settings. Known for their reliability and performance, these models are part of Bryant's esteemed line of heating and cooling solutions.

One of the standout features of the Bryant 551B is its two-stage cooling system, which allows for better humidity control and increased comfort. This ensures that homeowners can enjoy consistent temperatures while reducing energy consumption. The unit operates quietly, thanks to its noise-reducing technology, making it an ideal choice for bedrooms and living spaces.

On the other hand, the Bryant 551C builds upon this foundation with its variable-speed compressor. This technology allows the unit to adjust its cooling output according to the specific needs of the home. This results in seamless operation and even greater energy efficiency. Both models also incorporate Bryant's advanced control capabilities, which allow users to monitor and adjust settings remotely via smart devices, adding a layer of convenience and modernity to home climate control.

With an emphasis on durability, both the 551B and 551C feature a galvanized steel cabinet that protects against weather-related damage. The powder coat finish further enhances their resistance to rust and corrosion, ensuring a long lifespan and minimal maintenance.

Another significant characteristic of these units is their excellent Seasonal Energy Efficiency Ratio (SEER) ratings. The 551B boasts a SEER rating of up to 16, while the 551C takes it even further with ratings exceeding 20. This efficiency not only translates to lower energy bills for homeowners but also contributes to a reduced carbon footprint, making these units environmentally friendly options.

Both models are also designed to operate with eco-friendly refrigerants, aligning with modern energy standards and regulations aimed at reducing greenhouse gas emissions.

In summary, the Bryant 551B and 551C are exemplary choices for homeowners looking for reliable, efficient, and high-performing air conditioning solutions. With features such as two-stage and variable-speed compressors, advanced smart technology, and robust construction, these models stand out in the competitive HVAC market. They promise a comfortable indoor environment along with significant energy savings, making them a wise investment for the future.