MODEL NUMBER NOMENCLATURE — 551B

551B E X 090 000 DA

551B – Packaged Rooftop High Efficiency Electric

Voltage Designation

J208/230-1-60 P 208/230-3-60 E 460-3-60

T 575-3-60

X – No Heat Installed

(Field-installed electric heaters available)

Nominal Tons 036 – 3 048 – 4 060 – 5 072 – 6

090 – 7 1/2

102 – 8 1/2

120 – 10

150 – 12 1/2

Factory-Installed Option Code

Electric Heaters

000 – No factory-installed electric heaters

551B036-150

NOTE: The example model number 551BEX090000DA designates a 71/2 ton 460-3-60 volt electric cooling rooftop unit with an EconoMi$er.

ARI* CAPACITY RATINGS

UNIT

NOMINAL

STANDARD

NET COOLING CAP

TOTAL

 

 

SOUND

SEER†

EER

RATING

551B

TONS

CFM

(Btuh)

kW

 

 

(dB)

 

 

 

 

 

 

 

036

3

1200

36,000

3.21

13.00

11.20

76

048

4

1450

46,000

4.25

13.00

11.05

76

060

5

1750

61,000

5.55

13.00

11.00

80

 

 

 

 

 

 

 

 

UNIT

NOMINAL

STANDARD

NET COOLING CAP

TOTAL

 

SOUND

 

EER

RATING

IPLV

551B

TONS

CFM

(Btuh)

kW

 

(dB)

 

 

 

 

 

 

 

 

072

6

2100

74,000

6.70

11.00

80

**

090

71/

3000

90,000

8.18

11.00

82

11.6

 

2

 

 

 

 

 

 

102

81/

3000

102,000

9.44

10.80

82

10.9

 

2

 

 

 

 

 

 

120

10

3200

120,000

10.91

11.00

84

11.4

150

121/

4300

138,000

14.04

9.80

86

9.9

 

2

 

 

 

 

 

 

 

 

LEGEND

dB

Sound Levels

EER

Energy Efficiency Ratio

IPLV

Integrated Part-Load Value

SEER

Seasonal Energy Efficiency Ratio

*Air-Conditioning & Refrigeration Institute.

†Applies only to units with capacity of 65,000 Btuh or less. **IPLV is not applicable to single-compressor units.

NOTES:

1.Rated in accordance with ARI Standard 210/240 (036-120 units) or 360 (150 units) and 270 (036-120 units).

2.Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on:

Cooling Standard: 80 F db, 67 wb indoor entering-air temperature and 95 F db outdoor entering-air temperature.

IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F db outdoor entering-air temperature.

551B036-120

551B150

Units Only

Units Only

3.All 551B036-150 units are in compliance with ASHRAE 90.1-1999 Energy Standard for minimum SEER and EER requirements. Refer to state and local codes or visit the following website: http://solstice.crest.org/efficiency/ bcap to determine if compliance with this standard pertains to a given geo- graphical area of the United States.

California, Maryland, Washington, Wyoming, Massachusetts and various local and state building codes adopted the ASHRAE 90.1-99 efficiency standard on October 29, 2001.

71

Page 71
Image 71
Bryant 551A, 558F manual MODEL NUMBER NOMENCLATURE - 551B, 551B036-150, 551B E X 090 000 DA, Ari* Capacity Ratings