Physical Data (Heating)

APPENDIX II. PHYSICAL DATA (cont.)

Physical Data (Heating)

3 - 6 TONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

580J*04

580J*05

580J*06

580J*07

Gas Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

# of Gas Valves

 

 

1

 

1

 

1

 

1

 

 

Connection size

 

1/2” NPT

1/2” NPT

1/2” NPT

1/2” NPT

 

Nat. gas supply line press (in. w.g.)/(PSIG)

 

5--- 13 / 0.18--- 0.47

5--- 13 / 0.18--- 0.47

5--- 13 / 0.18--- 0.47

5--- 13 / 0.18--- 0.47

 

 

LP supply line press (in. w.g.)/(PSIG)

 

11---13 / 0.40--- 0.47

11---13 / 0.40--- 0.47

11---13 / 0.40---0.47

11---13 / 0.40--- 0.47

Heat Anticipator Setting (Amps)

 

 

 

 

 

 

 

 

 

 

 

1st stage

 

0.14

0.14

0.14

0.14

 

 

2nd stage

 

0.14

0.14

0.14

0.14

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas Heat

 

 

 

 

 

 

 

 

 

 

 

# of stages / # of burners (total)

 

1

/ 2

1

/ 2

1

/ 2

1

/ 2

 

LOW

 

 

Rollout switch opens / Closes

 

195

/ 115

195

/ 115

195

/ 115

195

/ 115

 

 

 

 

 

Temperature rise

 

25

/ 55

25 --- 55

25 --- 55

25 --- 55

 

 

# of stages / # of burners (total)

 

1 or 2 / 3

1

/ 3

1

/ 3

1

/ 3

 

 

 

 

MED

 

 

Rollout switch opens / Closes

 

195

/ 115

195

/ 115

195

/ 115

195

/ 115

 

 

 

 

 

Temperature rise

 

55

/ 85

35

/ 65

35

/ 65

35

/ 65

 

 

# of stages / # of burners (total)

 

 

---

1 or 2 / 3

1 or 2 / 3

1 or 2 / 3

 

 

 

 

 

HIGH

 

 

 

Rollout switch opens / Closes

 

 

---

195

/ 115

195

/ 115

195

/ 115

 

 

 

 

 

 

Temperature rise

 

 

---

50

/ 80

50

/ 80

50

/ 80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid Propane Heat

 

 

 

 

 

 

 

 

 

 

 

# of stages / # of burners (total)

 

1

/ 2

1

/ 2

1

/ 2

1

/ 2

 

LOW

 

 

Rollout switch opens / Closes

 

195

/ 115

195

/ 115

195

/ 115

195

/ 115

 

 

 

 

 

Temperature rise

 

25

/ 55

25 --- 55

25 --- 55

25 --- 55

 

 

# of stages / # of burners (total)

 

1 or 2 / 3

1 or 2 / 3

1 or 2 / 3

1 or 2 / 3

 

 

 

 

MED

 

 

Rollout switch opens / Closes

 

195

/ 115

195

/ 115

195

/ 115

195

/ 115

 

 

 

 

 

Temperature rise

 

55

/ 85

35

/ 65

35

/ 65

35

/ 65

 

 

# of stages / # of burners (total)

 

 

---

1 or 2 / 3

1 or 2 / 3

1 or 2 / 3

 

 

 

 

 

HIGH

 

 

 

Rollout switch opens / Closes

 

 

---

195

/ 115

195

/ 115

195

/ 115

 

 

 

 

 

 

Temperature rise

 

 

---

50

/ 80

50

/ 80

50

/ 80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low NOx Gas Heat

 

 

 

 

 

 

 

 

 

 

LOW

# of stages / # of burners (total)

 

1

/ 2

1

/ 2

1

/ 2

 

---

 

Rollout switch opens / Closes

 

195

/ 115

195

/ 115

195

/ 115

 

---

 

 

 

 

 

 

Temperature rise

 

20

/ 50

20

/ 50

20

/ 50

 

---

 

 

# of stages / # of burners (total)

 

1

/ 3

1

/ 3

1

/ 3

 

---

 

 

 

 

 

MED

 

 

 

Rollout switch opens / closes

 

195

/ 115

195

/ 115

195

/ 115

 

---

 

 

 

 

 

 

Temperature rise

 

30

/ 60

30

/ 60

30

/ 60

 

---

 

 

# of stages / # of burners (total)

 

 

---

1

/ 3

1

/ 3

 

---

 

 

 

 

 

 

HIGH

 

 

 

 

Rollout switch opens / Closes

 

 

---

195

/ 115

195

/ 115

 

---

 

 

 

 

 

 

 

Temperature rise

 

 

---

40

/ 70

40

/ 70

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

580J

51