APPENDIX IV. ELECTRICAL DATA (cont.)

580J*08

 

7.5 TONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

COMP (ea)

OFM (ea)

 

 

IFM

 

 

 

RANGE

 

 

 

 

 

 

 

 

 

V---Ph---Hz

 

 

 

 

 

Max

Max

EFF at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RLA

LRA

WATTS

FLA

TYPE

Full

FLA

 

MIN

 

MAX

WATTS

AMP Draw

 

 

 

 

 

 

 

Load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

1448

5.5

80%

5.2

208--- 3--- 60

187

 

253

25.0

164

325

1.5

Med Static

2278

7.9

81%

7.5

 

 

 

 

 

 

 

 

High Static

4559

15.8

81%

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

1448

5.5

80%

5.2

230--- 3--- 60

187

 

253

25.0

164

325

1.5

Med Static

2278

7.9

81%

7.5

 

 

 

 

 

 

 

 

High Static

4559

15.8

81%

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

1448

2.7

80%

2.6

460--- 3--- 60

414

 

506

12.2

100

325

0.8

Med Static

2278

3.6

81%

3.4

 

 

 

 

 

 

 

 

High Static

4559

7.8

81%

7.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

1379

2.5

80%

2.4

575--- 3--- 60

518

 

633

9.0

78

325

0.6

Med Static

3775

2.9

81%

2.8

 

 

 

 

 

 

 

 

High Static

1870

5.9

81%

5.6

 

 

 

 

 

 

 

 

 

 

 

 

 

580J*09

 

8.5 TONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

COMP (ea)

OFM (ea)

 

 

IFM

 

 

V---Ph---Hz

RANGE

 

 

 

 

 

 

 

 

 

RLA

LRA

WATTS

FLA

TYPE

Max

Max

EFF at Full Load

FLA

 

MIN

 

MAX

WATTS

AMP Draw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

1448

5.5

80%

5.2

208--- 3--- 60

187

 

253

29.5

195

325

1.5

Med Static

2120

5.5

80%

5.2

 

 

 

 

 

 

 

 

High Static

2694

10.5

80%

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

1448

5.5

80%

5.2

230--- 3--- 60

187

 

253

29.5

195

325

1.5

Med Static

2120

5.5

80%

5.2

 

 

 

 

 

 

 

 

High Static

2694

10.5

80%

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

1448

2.7

80%

2.6

460--- 3--- 60

414

 

506

14.7

95

325

0.8

Med Static

2120

2.7

80%

2.6

 

 

 

 

 

 

 

 

High Static

2694

4.6

80%

4.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

1379

2.5

80%

2.4

575--- 3--- 60

518

 

633

12.2

80

325

0.6

Med Static

1390

2.1

80%

2.0

 

 

 

 

 

 

 

 

High Static

3775

2.9

81%

2.8

 

 

 

 

 

 

 

 

 

 

 

 

 

580J*12

 

10 TONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

COMP (ea)

OFM (ea)

 

 

IFM

 

 

V---Ph---Hz

RANGE

 

 

 

 

 

 

 

 

 

RLA

LRA

WATTS

FLA

TYPE

Max

Max

EFF at Full Load

FLA

 

MIN

 

MAX

WATTS

AMP Draw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

2120

5.5

80%

5.2

208--- 3--- 60

187

 

253

30.1

225

325

1.5

Med Static

3775

10.5

81%

10.0

 

 

 

 

 

 

 

 

High Static

4559

15.8

81%

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

2120

5.5

80%

5.2

230--- 3--- 60

187

 

253

30.1

225

325

1.5

Med Static

3775

10.5

81%

10.0

 

 

 

 

 

 

 

 

High Static

4559

15.8

81%

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

2120

2.7

80%

2.6

460--- 3--- 60

414

 

506

16.7

114

325

0.8

Med Static

3775

4.6

81%

4.4

 

 

 

 

 

 

 

 

High Static

4559

7.8

81%

7.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std Static

1390

2.1

80%

2.0

575--- 3--- 60

518

 

633

12.2

80

325

0.6

Med Static

3775

2.9

81%

2.8

 

 

 

 

 

 

 

 

High Static

1870

5.9

81%

5.6

 

 

 

 

 

 

 

 

 

 

 

 

 

580J

67

Page 67
Image 67
Bryant 580J*04--12 appendix 580J*08 Tons, 580J*09 Tons, IFM Range, Rla Lra, Min Max

580J*04--12 specifications

The Bryant 580J*04--12 is a notable unit in the realm of residential air conditioning, exemplifying efficiency and reliability. Designed to offer optimal cooling solutions, this model incorporates advanced technologies and features that cater to modern comfort needs.

One of the standout features of the Bryant 580J is its energy efficiency. With a high Seasonal Energy Efficiency Ratio (SEER) rating, this air conditioning unit is engineered to minimize energy consumption while maximizing cooling performance. This efficiency not only reduces monthly utility bills but also aligns with environmentally friendly practices by using less energy.

The 580J model is equipped with advanced compressor technology, which contributes to its smooth and quiet operation. This is particularly important for residential settings, where noise can be a significant concern. The unit consistently maintains comfortable indoor temperatures without disruptive sound levels, enhancing the overall living experience.

This air conditioning system is designed with durability in mind. Constructed from robust materials, it withstands the rigors of various weather conditions. Additionally, its components are engineered for longevity, reducing the need for frequent repairs and maintenance. The 580J also comes with a comprehensive warranty, which provides homeowners with peace of mind regarding their investment.

Smart technology integration is another key feature of the Bryant 580J. Homeowners can take advantage of programmable thermostats and compatibility with home automation systems. This allows for remote access and control, making it easier to manage indoor climates efficiently. Users can set schedules, adjust temperatures, and monitor energy usage from their smartphones, adding a layer of convenience to everyday living.

Furthermore, the Bryant 580J includes advanced air filtration systems that improve indoor air quality. By effectively trapping dust, allergens, and pollutants, this unit promotes a healthier living environment. This feature is particularly beneficial for individuals with allergies or respiratory issues.

In summary, the Bryant 580J*04--12 stands out for its energy efficiency, quiet operation, durability, smart technology integration, and air quality improvement capabilities. By blending advanced engineering with user-friendly features, this model continues to be a top choice for homeowners seeking reliable and efficient air conditioning solutions.