Access Compressor Or Other Internal Cabinet Components

NOTE: It is not necessary to remove the top cover to gain access. Removing the top cover may cause grill panels, corner posts, louvers or coils to be damaged. It is recommended to protect the top cover from damage of tools, belt buckles, etc. while servicing from the top.

1.Should the unit height allow components to be accessed from the top of the unit, follow procedures for removing fan motor assembly. Access components through the top cap.

2.Large components may not be removed easily without having access from the top and side. Side access may allow procedures such as brazing, cutting, and removal easier. Follow procedures below:

a.Follow procedures to remove the fan motor assembly.

b.Air conditioning units only, remove the screws from the top of the electrical control panel. (Heat pumps will not have screws holding the electrical control panel in place at the top once the control box cover has been removed.)

c.Remove the base pan screws holding the control panel and lift off the unit.

Certain maintenance routines and repairs require removal of cabinet panels.

Remove Top Cover - Mid-Tier / Deluxe

1.Turn off all power to outdoor and indoor units.

2.Remove access panel.

3.Remove information plate.

4.Disconnect fan motor wires and cut wire ties. Remove wires from control box. Refer to unit wiring label.

5.Remove screws holding top cover to louver panels.

6.Lift top cover from unit.

7.Reverse sequence for reassembly.

Remove Fan Motor Assembly - Mid-Tier / Deluxe

1.Perform items 1 through 6 from above.

2.Remove nuts securing fan motor to top cover.

3.Remove motor and fan blade assembly.

4.Reverse sequence for reassembly.

5.Prior to applying power, check that fan rotates freely.

Control Box Cover—Legacy RNC Products

This panel contains much of the same information as the information plate mentioned previously, but is designed only to cover the control box.

Remove Top Cover—Legacy RNC Products

1.Turn off all power to outdoor an indoor units.

2.Remove 5 screws holding top cover to coil grille and coil tube sheet.

3.Remove 2 screws holding control box cover.

4.Remove 2 screws holding information plate.

5.Disconnect fan motor wires, cut any wire ties, and move wires out of control box and through tube clamp on back of control box.

6.Lift top cover from unit.

7.Reverse sequence for reassembly.

Remove Fan Motor Assembly—Legacy RNC Products

1.Perform items 1, 3, 4, and 5 above. (Note: item 2 is not required.)

2.Remove 4 screws holding wire basket to top cover.

3.Lift wire basket from unit.

4.Remove nuts holding fan motor to wire basket.

5.Remove motor and fan blade assembly.

6.Pull wires through wire raceway to change motor.

7.Reverse sequence for reassembly.

8.Prior to applying power, check that fan rotates freely.

9

Page 9
Image 9
Bryant R-22 service manual Access Compressor Or Other Internal Cabinet Components

R-22 specifications

The Bryant R-22 stands out in the landscape of residential heating and cooling systems with its combination of efficiency, durability, and modern technology. Designed primarily for homeowners seeking comfortable climate control solutions, the R-22 model delivers consistent performance throughout varying seasonal extremes.

One of the main features of the Bryant R-22 is its high energy efficiency. Rated with a SEER (Seasonal Energy Efficiency Ratio) that meets or exceeds industry standards, this air conditioning unit is designed to reduce energy consumption while providing optimal cooling. This not only helps in lowering monthly utility bills but also promotes environmentally responsible usage.

Another notable characteristic is the unit's durability. Constructed with a robust cabinet and high-quality components, the R-22 is built to withstand the rigors of daily use, with protective features that enhance its longevity. The cabinet comes with a powder-coated finish that resists corrosion and harsh weather conditions, ensuring that the unit stays functional and aesthetically pleasing for years.

The Bryant R-22 also incorporates advanced technology to improve user experience. One such innovation is the SmartSet technology, which allows homeowners to program their unit to optimize comfort levels according to their specific needs. This programmable capability enhances energy savings and ensures that the home remains at the desired temperature when residents are present.

Moreover, the unit features a Quiet Operating System that significantly reduces noise levels, making it suitable for residential areas where noise might be a concern. The design minimizes vibrations and optimizes airflow, creating a comfortable environment without disruptive sounds.

For added convenience, the Bryant R-22 is compatible with various thermostat options, including Wi-Fi-enabled models. This allows users to control their home's climate from anywhere using a smartphone app, facilitating effortless adjustments and monitoring of energy usage.

Finally, the Bryant R-22 is backed by a solid warranty, providing peace of mind for homeowners. This commitment to quality and customer satisfaction is a testament to Bryant’s dedication to producing reliable and efficient HVAC solutions. Overall, the Bryant R-22 is an exemplary choice for those looking to enhance their home comfort with the latest in HVAC technology.