37
Ultimate 106 Edition 2 Issue 3 - 24.12.02 5129
Technical information
RTTE
Hereby Promotion & Display Technology Ltd. declares that this
Ultimate 106 is in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC.
The Declaration of Conformance for the Ultimate 106 is published on the
Website: http.//www.pdtuk.com/archive/certificates/ultimate/default.htm
Installation information
The Ultimate 106 connects to one exchange line and six (2 wire)
telephone extensions.
Signalling
DTMF.
Pulse dialling (typical 10 pps).
RECALL to external line – duration: 100ms.
type: timed break.
RECALL detection from extension – duration: 85ms to 200ms,
type: timed break.
REN
REN of the Ultimate 106 is 4.
Maximum REN per extension is 2.
Environmental conditions
Temperature range: (storage) –10C to 60C, (operating) 0C to 55C.
Humidity range: (storage) 65%, (operating) 60% maximum.
Ring cadences
Internal: 1s ON, 2s OFF.
External: 0.4s ON, 0.2s OFF,0.4s ON, 2s OFF.
Door-phone: 0.5s ON, 2.5s OFF.
Alarm call: 0.5s ON, 0.3s OFF,0.2s ON, 2s OFF.
Internal Ring-back: 0.2s ON, 0.2s OFF,0.2s ON, 0.2s OFF, 0.2s ON, 2s OFF.
External Ring-back: 0.5s ON, 0.3s OFF,0.2s ON, 2s OFF.
Power Supply (internal)
Power supply 220-240V AC 50/60Hz.
Power consumption 45W.
Weight
Weight 1.5kg.
Dimensions (approx.)
Height: 200mm. Width: 295mm. Depth: 48mm (52mm from wall).