Ultimate 106 – Edition 2 – Issue 3 - 24.12.02 – 5129

Technical information

RTTE

Hereby Promotion & Display Technology Ltd. declares that this

 

Ultimate 106 is in compliance with the essential requirements and other

 

relevant provisions of Directive 1999/5/EC.

 

The Declaration of Conformance for the Ultimate 106 is published on the

 

Website: http.//www.pdtuk.com/archive/certificates/ultimate/default.htm

 

 

Installation information

The Ultimate 106 connects to one exchange line and six (2 wire)

 

telephone extensions.

 

 

Signalling

DTMF.

 

Pulse dialling (typical 10 pps).

 

RECALL to external line – duration: 100ms.

 

type: timed break.

 

RECALL detection from extension – duration: 85ms to 200ms,

 

type: timed break.

 

 

REN

REN of the Ultimate 106 is 4.

 

Maximum REN per extension is 2.

 

 

Environmental conditions

Temperature range: (storage) –10C to 60C, (operating) 0C to 55C.

 

Humidity range: (storage) 65%, (operating) 60% maximum.

 

 

Ring cadences

Internal: 1s ON, 2s OFF.

 

External: 0.4s ON, 0.2s OFF, 0.4s ON, 2s OFF.

 

Door-phone: 0.5s ON, 2.5s OFF.

 

Alarm call: 0.5s ON, 0.3s OFF, 0.2s ON, 2s OFF.

 

Internal Ring-back: 0.2s ON, 0.2s OFF, 0.2s ON, 0.2s OFF, 0.2s ON, 2s OFF.

 

External Ring-back: 0.5s ON, 0.3s OFF, 0.2s ON, 2s OFF.

 

 

Power Supply (internal)

Power supply 220-240V AC 50/60Hz.

 

Power consumption 45W.

 

 

Weight

Weight 1.5kg.

 

 

Dimensions (approx.)

Height: 200mm. Width: 295mm. Depth: 48mm (52mm from wall).

 

 