Troubleshooting Congestion

Troubleshooting

5.4TROUBLESHOOTING CONGESTION

If the bandwidth of your SmartSwitch 9A100 begins to decrease, and if connections are being lost or packets are being dropped at a high rate, it’s possible that your switch is becoming congested. Congestion can occur on the port level, the global switch level, or both levels.

If you suspect that your SmartSwitch 9A100 switch is experiencing congestion, follow the steps outlined below to diagnose and resolve the cause of congestion.

5.4.1Diagnosing Congestion

1.Enter the show portstats command, and take the default of (all).

2.If cells are not being dropped on all ports, proceed to the “Port Congestion” section.

3.If cells are being dropped on all ports, the indication is global congestion. Proceed to the “Global Congestion” section.

5.4.2Global Congestion

1.Is the total cell drop rate equal to the Unknown VC cell drop rate?

If yes, the switch is improperly set up. Check the switch configuration.

If no, this indicates global congestion. Continue.

2.Set the porttrafficcongestion values to those recommended in the “QoS Queue Allocation Guidelines” section. Has the congestion subsided?

If yes, you are done.

If no, continue.

3.Have you changed the EPD threshold?

If yes, replace it to the default setting. If congestion subsides, you are done.

If no, continue.

4.Enter the show cacinfo command for each port. Is the allocated bandwidth small and is the traffic mostly UBR?

If no, go back to step 4 and check next port.

If yes, continue.

5.Enter the show porttrafficcongestion command. Is the UBR queue Max threshold large?

If no, go back to 4.

If yes, continue.

6.Reduce the UBR queue Max threshold by a small amount, then wait a few minutes.

7.Enter the show portstats command, and take the default of all. Is the number of cells dropped increasing for this port, and quickly decreasing for all other ports?

If yes, proceed to the “Port Congestion” section.

If no, continue.