Detecting when multiple documents have been fed together

Enable the [Double Feed Detection] check box in the [Feeding] tab. Either [Detect by Length] or [Detect by Ultrasonic] can be enabled singly, or both together

Hint

Even if Detection by ultrasonic is enabled, double feeds may not be detected if the document size is small.

Saving data by document bundle (batch separation)

If using batch separation, you can save the data in units of the document bundles placed in the tray. In this case, set the scanner drivers as described below.

Set the [Feeding Option] in the [Feeding] tab to [Panel- Feeding] or [Automatic Feeding].

Set the [Batch Separation] in the [Others] tab to [Auto] or [Panel].

When the [Batch Separation] is set to [Auto], and the next documents have been set so scanning is continuous, the batches are separated.

Chapter 10 Practical Examples

When [Batch Separation] is set to [Panel], and the [New File] key on the control panel is pressed, batch separation is implemented, so the batches can be separated after multiple bundles have been scanned.

Hint

When [Feeding Option] on the [Feeding] tab is set to [Standard Feeding], [Auto] and [Panel] in [Batch Separation] are disabled.

To use the batch separation function, suitable application software is required.

Registering Your Settings

You can register the scanning conditions so that you can use them next time.

Registering scanning conditions

Press the [Save] button in the user settings to add a name to the scan conditions and implement registration. When you want to use the registered scanning conditions, select the registered name to apply the registered set conditions.

10-10