Canon Data Packet Configuration, Control Command Packet Format PC - RE-350, Header, ID number

Models: RE-350

1 63
Download 63 pages 27.1 Kb
Page 16
Image 16

1.8 Data Packet Configuration

Control Command Packet Format (PC —> RE-350)

The PC can request an operation from the RE-350using this command.

Header

ID number

Command number

 

Parameter

10h

* *h

* *h

MSH

 

LSH

 

 

 

 

 

 

C-Response Data Packet Format (PC <— RE-350)

The PC can determine whether the RE-350could perform and finish an operation command given to it by the PC or failed to perform the operation command given to it by the PC.

Header

ID number

Response number

Parameter

 

A0h

* *h

* *h

MSH

 

LSH

 

 

 

 

 

 

Event Data Packet Format (PC <— RE-350)

When the RE-350's {RS-232} button is pushed, the RE-350will send this packet to the PC.

Header

ID number

Event number

Parameter

 

 

 

 

 

 

20h

* *h

* *h

MSH

 

LSH

 

 

 

 

 

 

E-Response Data Packet Format (PC —> RE-350)

When the PC receives the “Event Data Packet” from the RE-350, the PC should respond to the RE-350with this data packet.

Header

ID number

Response number

Parameter

 

 

 

 

 

 

B0h

* *h

* *h

MSH

 

LSH

 

 

 

 

 

 

FP Data Packet Format (PC <— RE-350)

In [NOTIFICATION] Mode, the RE-350can notify the PC of the condition of each button

and LED using this data

packet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

ID number

FP data number

Parameter

 

 

 

 

 

 

 

 

 

 

30h

* *h

* *h

MSH

 

LSH

 

 

 

 

 

 

 

 

 

16

Page 16
Image 16
Canon Data Packet Configuration, Control Command Packet Format PC - RE-350, C-Response Data Packet Format PC - RE-350