3.5 Detail Commands
Detail: Manual Access To
•Function:
Sets a designated sharpness position, which is determined by the parameter of this command. The result is the same as rotating the manual control knob on the front panel.
Note:
The control knob’s physical position is not updated by this command.
This command simply modifies the target exposure default value which is $80.
•Available parameter value:
LSH: $ 00 (less detail)~ $ FF (more detail)
•Timing of the
•The parameter of the
•The maximum operation time (msec): 500 millisecond
•Command format:
Header | ID number | Command | Parameter MSH Parameter LSH |
$10
$ 8 *
$3 0
$ 0 0
$ * *