2.2 System Control Commands Table

 

 

 

Maximum

1 byte

2 byte

3 byte

4 byte

5 byte

#

Name

Description

operation

Header

ID number

Command

Param(H)

Param(L)

time(ms)

 

 

 

 

 

 

 

 

 

Select Input Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Select Document Video

Output Camera signal

500

$10

$8*

$50

$00

$00

 

 

 

 

 

 

 

 

 

2

Select External video

Output External signal

500

$10

$8*

$50

$01

$00

 

 

 

 

 

 

 

 

 

 

Light on/off Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Lights On ††

Turn Light On

500

$10

$8*

$58

$00

$00

4

Lights Off ††

Turn Light Off

500

$10

$8*

$58

$01

$00

5

Backlight On ††

Turn Backlight On

500

$10

$8*

$59

$00

$00

6

Backlight Off ††

Turn Backlight Off

500

$10

$8*

$59

$01

$00

 

LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

LED Normal

Set LED Condition Normal

500

$10

$8*

$68

$**

$00

 

 

 

 

 

 

 

 

 

8

LED On

Turn LED On

500

$10

$8*

$69

$**

$00

 

 

 

 

 

 

 

 

 

9

LED Off

Turn LED Off

500

$10

$8*

$6A

$**

$00

 

 

 

 

 

 

 

 

 

10

LED Blink

Blink LED

500

$10

$8*

$6B

$**

$00

 

 

 

 

 

 

 

 

 

 

Communication Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

OFF Line

Set to [OFF LINE] Mode

500

$10

$8*

$70

$00

$00

 

 

 

 

 

 

 

 

 

12

ON Line

Set to [ON LINE] Mode

500

$10

$8*

$70

$01

$00

 

 

 

 

 

 

 

 

 

13

Notification

Set to [Notification] Mode

500

$10

$8*

$70

$02

$00

 

 

 

 

 

 

 

 

 

 

Status Request

 

 

 

 

 

 

 

14

Status of Group A

Request Status Group A

100

$10

$8*

$80

$00

$00

 

 

 

 

 

 

 

 

 

15

Status of Group B

Request Status Group B

100

$10

$8*

$80

$01

$00

 

 

 

 

 

 

 

 

 

16

Status of Button

Request Button condition

100

$10

$8*

$81

$00

$00

 

 

 

 

 

 

 

 

 

17

Status of WB Control

Request WB vol. position

100

$10

$8*

$82

$00

$00

 

 

 

 

 

 

 

 

 

18

Status of EXP Control

Request EXP vol. position

100

$10

$8*

$82

$01

$00

 

 

 

 

 

 

 

 

 

19

Status of Detail Vol.

Request Detail vol. position

100

$10

$8*

$82

$02

$00

 

 

 

 

 

 

 

 

 

20

Status of AWB Result

Request AWB result data

100

$10

$8*

$83

$00

$00

 

 

 

 

 

 

 

 

 

21

Name of Equipment

Request Name of equip.

100

$10

$8*

$88

$00

$00

 

 

 

 

 

 

 

 

 

22

Version of ROM

Request ROM version

100

$10

$8*

$88

$01

$00

 

 

 

 

 

 

 

 

 

 

Set to Special Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

Set to Temporary Mode

Set to temp. mode

100

$10

$8*

$F0

$00

$00

 

 

 

 

 

 

 

 

 

24

Set to Service Mode

Set to service mode

100

$10

$8*

$F1

$FF

$FF

 

 

 

 

 

 

 

 

 

25

Set to Data Read Out

Set to data read mode

100

$10

$8*

$F1

$FF

$00

 

 

 

 

 

 

 

 

 

††The RE-350responds with a C-response data packet immediately after the reception of this command, but it is still working on the AWB adjustment.

20

Page 20
Image 20
Canon RE-350 manual System Control Commands Table, Led