LED: On

Function:

The LED indicated by the parameter data will be turned on. This command is available in the [NOTIFICATION] Mode. If the RE-350receives this command from the PC in another mode, the RE-350will send a “C-response Packet” with the Mode Error response.

The available parameter value: LSH: $00 ~ $FF

Timing of the “C-response Packet” sent to the PC: Right after this setting is done.

The parameter of the “C-response Packet”: $0000 fixed

The maximum operation time (msec): 500 millisecond

Command format:

Header

ID number

Command

Parameter MSH Parameter LSH

$10

$ 8 *

$ 6 9

$ * *

$ 0 0

The bit assignment for the parameter data:

Each bit corresponds to each LED on the operation panel.

D15

D14

D13

D12

D11

D10

D9

D8

RS-232

Input select

NEGA

WB Auto

B/W

Focus Auto

Lights

Backlight

 

 

 

 

 

 

 

 

42

Page 42
Image 42
Canon RE-350 manual LED On