ALL CONFIGURATIONS REQUIRE SERVICE ACCESS AREA SHOWN BELOW

 

 

 

 

 

19.3

 

 

 

 

 

F

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

19.3

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

AIR OUT

NRP

 

NRP

AIR OUT

 

 

 

 

 

BSP

 

 

 

 

 

 

 

a50-8436

 

 

 

 

 

 

 

BSP

 

 

T

 

 

 

 

NRP

 

RETURN AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN AIR

 

 

 

 

S

 

4

 

 

 

 

C

 

 

 

 

 

 

 

 

1

 

 

 

2

 

NRP

 

Q

 

5

 

 

 

 

R

 

 

 

 

 

 

 

U

 

 

 

 

 

3

 

NRP

4

Control Box

 

 

 

02

CAP+MSP

 

 

 

 

 

 

Control Box

3

 

3

 

4

 

 

 

 

 

3 L

P

 

 

 

N

 

 

4 5

01

2

 

 

NRP

1

 

 

M

 

 

 

 

 

 

 

 

 

M K

 

 

 

 

 

 

L

 

CSP+CAP+MSP

K

 

CSP

 

 

 

 

 

 

 

 

 

 

ANOTE 5

 

 

REAR RETURN TOP DISCHARGE

 

FRONT RETURN TOP DISCHARGE

4.3

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

RETURN AIR

 

 

 

 

 

 

 

BSP

 

 

 

 

F

 

 

 

 

 

 

 

 

E

 

 

 

BSP

 

 

 

BSP

 

 

 

AIR OUT

 

NRP

AIR OUT

 

 

 

 

 

4

 

NRP

 

 

 

 

 

 

 

 

 

 

 

 

5

 

1

 

 

 

 

 

 

 

 

 

RETURN AIR

 

 

 

 

 

NRP

 

 

NRP

4

3

 

4

 

 

 

 

2

 

 

 

CAP+MSP

 

 

5

 

 

 

Control Box

 

 

 

 

 

 

 

 

 

 

 

 

 

4

3

4

Control Box

 

 

 

2

 

5

 

 

 

 

4

 

 

 

 

 

 

3

4

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

4

5

 

CSP

 

 

NRP

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSP+CAP+MSP

 

 

 

 

 

SIDE

 

 

 

 

 

 

 

SERVICE ACCESS

 

 

 

 

 

 

 

(SEE NOTE)

 

 

 

 

SERVICE ACCESS

 

REAR RETURN FRONT DISCHARGE

 

 

 

 

91 CM

 

 

 

 

 

 

 

 

 

FRONT RETURN REAR DISCHARGE

FRONT AND BACK

 

 

 

 

LEGEND

BSP — Blower Service Panel

CAP — Control Access Panel

CSP — Compressor Service Panel

MSP — Motor Service Panel

NRP Non-Removable Panel

NOTES:

1.All dimensions in centimeters.

2.Units require 0.9 m clearance for water connections, CAP, CSP, MSP, and BSP service access.

3.Overall cabinet height dimension does not include duct flange when in top discharge configuration.

4.Overall cabinet width dimension does not include filter rack and duct flange when on front or back dis- charge configuration.

5.Side service access must be 0.9 m on either side that connections are made. If no connections are made on a side, then service access can be 15 mm minimum.

6.While access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service.

7.Water inlet and water outlet connections are available on either side (left or right) of the unit. Two MPT plugs are shipped loose in a plastic bag tied to the water leg in front of the unit. Installer must plug water inlet/outlet side not being connected to.

8.Condensate drain is available on either side (left or right) of unit. Drain hose and drain connection will be tied inside the unit. Installer must untie the drain hose and connect to the condensate drain hole of installer’s choice.

9.Electrical access is available on either side (left or right) of unit and is also available (left or right) in the front of the unit.

10.Overall depth — add 7.9 cm for 2.5 or 5 cm filter. Add 13 cm for 10 cm filter.

1

2

3

4

5

CONNECTIONS

50VQP084-120

50VQP150

Water Inlet (See Note 7)

11/2 in. FPT

2 in. FPT

Water Outlet (See Note 7)

11/2 in. FPT

2 in. FPT

Condensate Drain (See Note 8)

1 in. FPT

1 in. FPT

High Voltage Access (See Note 9)

13/8 in.

13/8 in.

Low Voltage Access (See Note 9)

7/8 in.

7/8 in.

 

 

OVERALL

 

DISCHARGE

 

 

WATER

 

 

ELECTRICAL

 

 

RETURN AIR

 

 

 

 

CONNECTIONS (cm)

 

 

 

 

CONNECTIONS (cm)

 

 

CABINET (cm)

 

CONNECTIONS (cm)

 

 

KNOCKOUTS (cm)

 

 

UNIT

Duct Flange

 

 

 

 

 

(Using Return Air Opening)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50VQP

A

B

 

C

D

E

 

K

L

M

 

 

 

 

 

 

S

T

 

 

 

 

Supply

Supply

F

1-Water

1-Water

3-

N

O1

O2

P

Q

R

Return

Return

U

V

 

Depth

Width

 

Height

 

 

Width

Depth

 

Inlet

Outlet

Condesate

 

 

 

 

 

 

Depth

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

084-120

86.4

134.9

 

200.7

44.5

44.6

45.1

78.7

7.6

68.6

65.1

78.7

96.4

87.7

2.5

7.6

121.9

82.2

113.3

6.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

86.4

134.9

 

200.7

54.4

44.6

45.1

78.7

7.6

68.6

65.1

78.7

96.4

87.7

2.5

7.6

121.9

82.2

113.3

6.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 2 — 50VQP084-150 Unit Dimensions

4

Page 4
Image 4
Carrier 50VQP084-300 specifications A50-8436, 50VQP084-150 Unit Dimensions