4--3

T-343

Table 4-1 Preventative Maintenance Actions and Schedule (Continued)

 

 

 

 

 

 

Extended

 

 

 

 

Standard Service

Service

 

 

 

Perform

Interval Units

Interval

Description of Procedure

Reference

 

at

 

 

Units

Paragraph

 

Pre-Trip

 

 

 

 

 

 

 

 

 

 

 

Inspection

Every

Annually

Annually

 

 

 

 

1000

or Every

or Every

 

 

 

 

Hours

3000 Hours

3000 Hours

 

 

 

 

 

 

 

20.Check water pump bearing end play

See Engine

 

 

X

 

X

Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21.Change fuel filter

4.4.3

 

 

 

X

X

 

 

 

 

 

 

 

22.Clean crankcase breather

4.4.14

 

 

 

X

X

 

 

 

 

 

 

 

23.Remove and check engine/generator shockmounts for cracks, cuts, splits, abrasion or flaring

4.6.2

 

 

 

X

X

 

 

 

 

 

 

 

24.Check and, if required, replace poly V-Belt

4.4.9

 

 

 

X

X

 

 

 

 

 

 

 

25.Clean and flush coolant system

4.4.5

 

 

 

X

See Note 3

 

 

 

 

 

 

 

26.Check starter condition

See Engine

 

 

 

X

X

Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27.Check engine compression

See Engine

 

 

 

X

X

Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28.Check and adjust injector nozzles

See Engine

 

 

 

X

X

Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29.Perform generator maintenance

4.5.1

 

 

 

X

X

 

 

 

 

 

 

 

After Starting Generator Set, perform

the following:

 

 

 

 

 

 

 

 

 

 

 

30.Check total time meter operation (Allow engine to run for 10 minutes)

 

 

X

 

 

 

 

 

 

 

 

 

 

31.Listen for abnormal bearing noise

 

 

X

 

 

 

 

 

 

 

 

 

 

32.Check fuel lines, lube oil lines and filters for leaks

 

 

X

 

 

 

 

 

 

 

 

 

 

33.Check exhaust system for leaks

 

 

X

 

 

 

 

 

 

 

 

 

 

34.Check with voltmeter. Generator output should be 490 volts AC +/-- 10 volts

 

 

 

 

 

 

(engine, 1800 RPM) with a nominal frequency of 60Hz +/- 0.1%

 

 

X

 

 

 

Turn refrigeration unit on and check generator 1800 RPM minimum under full load (15 kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.500 hour interval in extreme operation conditions

2.250 hour interval in extreme operation conditions

3.Four years or 4000 hours if unit is factory charged with long life (red/orange) coolant