Line Card Memory
Installing a SODIMM
Use the following procedure to install a SODIMM.
Note If you are installing both SODIMMs, be sure to install SODIMM0 first.
Step 1 Attach an
Step 2 Place the line card on an antistatic mat so that the faceplate is nearest to you.
Step 3 If there is a retaining clip, check to make sure that it has not been damaged or bent (Figure 28).
Note Some line cards do not require a retaining clip.
Figure 28 SODIMM Socket Retaining Clip
75757
Caution If the retaining clip is damaged, do not use it. This can damage the SODIMM socket.
Step 4 Locate the route memory socket on the line card.
Step 5 Remove the new SODIMM from its protective antistatic bag.
Caution Grasp the edges of the SODIMM only. Do not touch the integrated circuit devices on the SODIMM, the metal traces or fingers along the edge of the SODIMM, or the pins in the SODIMM socket.
Step 6 Line up the SODIMM key with the key in the board socket (Figure 29).
ATM Line Card Installation and Configuration
| 55 |
| |
|
|