17-18
Cisco ONS 15600 Procedure Guide, R8.0
Chapter17 DLPs E100 to E199
DLP- E120 Remove the Narrow CRMs
Step 3 From the Auto-refresh drop-down list choose one of the following options:
None: This option disables the auto-refresh feature.
15 Seconds: This option sets the window auto-refresh to 15-second time intervals.
30 Seconds: This option sets the window auto-refresh to 30-second time intervals.
1 Minute: This option sets the window auto-refresh to one-minute time intervals.
3 Minutes: This option sets the window auto-refresh to three-minute time intervals.
5 Minutes: This option sets the window auto-refresh to five-minute time intervals.
Step 4 Click Refresh. The PM counts for the new time interval appear.
Depending on the selected auto-refresh interval, the PM counts shown automatically update when each
refresh interval is complete. If the auto-refresh interval is set to None, the PM counts are not updated
unless you click the Refresh button.
Step 5 Return to your originating procedure (NTP).
DLP-E120 Remove the Narrow CRMs
Step 1 Use a Phillips screwdriver to loosen the three screws (approximately five revolutions each) on the
existing cable routers (Figure17-2).
Purpose This task removes existing narrow CRMs on the ONS15600 bay so that
you can install the wide CRMs.
Tools/Equipment Phillips screwdriver, 6 inches long
Retaining screws
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None