17-23
Cisco ONS 15600 Procedure Guide, R8.0
Chapter17 DLPs E100 to E199
DLP- E126 Provision the IIOP Listener Port on the CTC Computer
Other Constant—If Port 683 is not used, type the IIOP port specified by your firewall administrator.
Step 3 Click Apply.
Step 4 When the Change Network Configuration message appears, click Yes.
Both Timing and Shelf controllers (TSCs) reboot, one at a time. The reboot will take approximately
15 minutes.
Step 5 Return to your originating procedure (NTP).
DLP-E126 Provision the IIOP Listener Port on the CTC Computer
Step 1 From the Edit menu, choose Preferences.
Step 2 In the Preferences dialog box, click the Firewall tab.
Step 3 In the CTC CORBA (IIOP) Listener Port area, choose a listener port option:
Default - Variable—Use to connect to ONS15600s from within a firewall or if no firewall is used
(default).
Standard Constant—Use Port 683, the CORBA default port number.
Other Constant—If Port 683 is not used, enter the IIOP port defined by your administrator.
Step 4 Click Apply. A warning appears telling you that the port change will apply during the next CTC login.
Step 5 Click OK.
Step 6 In the Preferences dialog box, click OK.
Step 7 To access the ONS15600 using the IIOP port, log out of CTC then log back in. (To log out, choose Exit
from the File menu.)
Step 8 Return to your originating procedure (NTP).
Purpose This task selects the IIOP listener port on CTC.
Tools/Equipment IIOP listener port number from LAN or firewall administrator
Prerequisite Procedures NTP-E21 Verify Card Installation, page 4-2
DLP-E26 Log into CTC, page 16-33
Required/As Needed Required only if the computer running CTC resides behind a firewall
Onsite/Remote Onsite or remote
Security Level Provisioning or higher