17-20
Cisco ONS 15600 Procedure Guide, R8.0
Chapter17 DLPs E100 to E199
DLP- E121 Replace the Existing 600-mm Kick Plates with 900-mm Kick Plates
DLP-E121 Replace the Existing 600-mm Kick Plates with 900-mm Kick Plates
Step 1 Using the screwdriver, remove the five screws located on the 600-mm (23.6-inch) kick plate on the front
of the bay.
Step 2 Repeat Step 1 for the kick plate at the rear of the bay.
Step 3 Place a 900-mm (35.4-inch) kick plate (700-16756-XX) at the front of the bay and use a screwdriver to
install the five screws.
Step 4 On the right side of the bay, install the side kick plate (700-16758-XX) using the two appropriate screws.
Note Make sure the side kick plate’s larger flange is on the floor.
Step 5 Repeat Step 4 for the left and rear kick plates.
Step 6 Return to your originating procedure (NTP).
DLP-E122 Manual Switch the Node Timing Reference
Step 1 In node view, click the Maintenance > Timing > Source tabs. The Timing source window appears.
Step 2 In the Reference drop-down list for the desired Clock, choose the desired reference.
Step 3 In the Operation drop-down list, choose Manual.
Purpose This task removes the existing 600-mm (23.6-inch) kick plates so you can
install the 900-mm (35.4-inch) kick plates. You should install 900-mm
(35.4-inch) kick plates if you plan to install the wide CRMs.
Tools/Equipment 900-mm kick plate kit (53-2178-XX)
Screwdriver
Retaining screws
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None
Purpose This task commands the network element (NE) to switch to the timing
reference you have selected if the synchronization status message (SSM)
quality of the requested reference is not less than the current reference.
Tools/Equipment None
Prerequisite Procedures DLP-E26 Lo g into CTC, page 16-33
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Maintenance or higher