17-33
Cisco ONS 15600 Procedure Guide, R8.0
Chapter17 DLPs E100 to E199
DLP- E142 Install the Narrow CRMs
DLP-E142 Install the Narrow CRMs
Step 1 On the bottom left and bottom right, install the cable radius (2 screws).
Step 2 Lift the right-side narrow CRM and align it with the three screw holes you will use to mount the CRM.
Step 3 Use a Phillips screwdriver to tighten the three screws, starting with the bottom screw and moving up
(Figure 17-2 on page 17-19).
Step 4 Repeat this procedure for the router on the other side.
Step 5 Return to your originating procedure (NTP).
Purpose This task installs narrow CRMs on the ONS 15600 bay.
Tools/Equipment Narrow CRM kit (53-2193-01) (optional)
Fiber radiuses (2; left and right)
Narrow CRMs (2; left and right)
6-32 panhead screws (4; for fiber radiuses)
8-32 panhead screws (6; for narrow CRMs)
Phillips screwdriver, 6 inches long
Retaining screws
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None