13-27
Catalyst2950 and Catalyst2955 Switch Software Configuration Guide
78-11380-10
Chapter13 Configuring LRE Displaying LRE Status
The CPE device finishes resetting. Ethernet connectivity is available but at low speeds. Upgrade data
transfer begins.
00:23:55: %LINEPROTO-5-UPDOWN: Line protocol on Interface
LongReachEthernet0/1, changed state to down
Upgrade data transfer is complete. Reset the CPE device.
00:23:56: %LINK-3-UPDOWN: Interface LongReachEthernet0/1, changed state to up
The CPE device has finished resetting. The desired profile is applied.
00:23:58: %LRE_LINK-3-UPDOWN: Interface Lo0/1, changed state to UP
00:23:59: %LINK-3-UPDOWN: Interface LongReachEthernet0/1, changed state to up
00:24:02: %LINEPROTO-5-UPDOWN: Line protocol on Interface
LongReachEthernet0/1, changed state to up
Operation resumes in the profile link up state.
Switch#
Displaying LRE Status
To display the LRE information, use one or more of the privileged EXEC commands in Table13-10.
For detailed information about the fields in the command outputs, refer to the command reference for
this release.
Table13-10 Commands for Displaying LRE Information
Command Purpose
show controllers ethernet-controller Display the Ethernet link send and receive statistics on a Fast Ethernet port.
show controllers lre profile details Display information about the LRE profiles.
show controllers lre status Display the LRE link statistics and profile information on an LRE switch port.