17-3
Catalyst 3550 Multilayer Switch Software Configuration Guide
78-11194-03
Chapter17 Configuring System Messa ge Logging Configuring System Message Logging
This example shows a partial switch system message:
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to up
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed
state to down 2
*Mar 1 18:46:11: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
18:47:02: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
*Mar 1 18:48:50.483 UTC: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
Default System Message Logging Configuration
Table17-2 show s the de faul t syste m messa ge log ging c onfig urati on.
MNEMONIC Text string that uniquely describes the message.
description Text string containing detailed information about the event being reported.
Table17-1 System Log Message Elements (continued)
Element Description
Table17-2 Default System Message Logging Configuration
Feature Default Setting
System message logging to the console Enabled.
Console severity Debugging (and numerically lower levels; see
Table17-3 on pa ge 17-9).
Logging buffer size 4096 bytes.
Logging history size 1 message.
Timestamps Disabled.
Synchronous logging Disabled.
Logging server Disabled.
Syslog server IP address None configured.
Server facility Local7 (see Table17-4 on page 17-12).
Server severity Informational (and numerically lower levels; see
Table17-3 on pa ge 17-9).