Fan Failures

Chapter 1 Cisco 7200 VXR Product Overview

Functional Overview

Following is sample output of the show environment all command:

NPE300(boot)# show environment all

Power Supplies:

 

 

 

Power Supply 1

is empty.

 

Power Supply 2

is Zytek AC Power Supply. Unit is on.

Temperature readings:

 

chassis

inlet

 

measured

at 26C/78F

chassis

outlet

1

measured

at 28C/82F

chassis

outlet

2

measured

at 29C/84F

chassis

outlet

3

measured

at 33C/91F

Voltage readings:

 

 

 

+3.45 V

 

measured at

+3.46 V

+5.15 V

 

measured at

+5.25 V

+12.15 V

 

measured at

+12.24 V

-11.95 V

 

measured at

-11.81 V

Envm stats saved 138 time(s) since reload

Fan Failures

When the system power is on, all three fans should be operational. The system continues to operate if a fan fails; however, if the air temperature exceeds a defined threshold, the system controller displays warning messages on the console terminal, and if the temperature exceeds the shutdown threshold, the system controller shuts down the system.

If the system does shut down because the temperature exceeded the shutdown threshold, the system displays the following message on the console screen and in the environment display when the system restarts:

Queued messages:

%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown

For complete descriptions and instructions for the environmental monitor commands, refer to the Configuration Fundamentals Configuration Guide and Configuration Fundamentals Command Reference publications, which are available on Cisco.com or the Documentation DVD.

Cisco 7200 VXR Installation and Configuration Guide