Following is sample output of the show environment last command:

NPE300(boot)# show environment last

chassis

inlet

previously measured at 26C/78F

chassis outlet 1

previously measured at 28C/82F

chassis outlet 2

previously measured at 29C/84F

chassis outlet 3

previously measured at 33C/91F

+3.45

V

 

previously measured at +3.46

+5.15

V

 

previously measured at +5.23

+12.15

V

previously measured at +12.24

-11.95

V

previously measured at -11.81

last shutdown reason - power supply shutdown

The show environment table command displays the temperature and voltage thresholds for each temperature sensor and for each monitored status level. These thresholds are related to those listed in Table 1-36and Table 1-38. The display also lists the shutdown threshold for the system.

Following is sample output of the show environment table command for a Cisco 7206VXR that has an installed NPE-300:

NPE300(boot)# show environment table

Sample Point

LowCritical

LowWarning

HighWarning

HighCritical

chassis

inlet

 

 

40C/104F

50C/122F

chassis

outlet 1

 

 

43C/109F

53C/127F

chassis

outlet 2

 

 

75C/167F

75C/167F

chassis

outlet 3

 

 

50C/122F

60C/140F

+3.45

V

 

+3.26

+3.34

+3.55

+3.63

+5.15

V

 

+4.86

+4.99

+5.31

+5.43

+12.15

V

 

+11.39

+11.67

+12.62

+12.91

-11.95

V

 

-9.52

-10.73

-13.16

-14.38

System shutdown for chassis inlet is 75C/167F

System shutdown for chassis outlet 1 is 58C/136F

System shutdown for chassis outlet 2 is 75C/167F

System shutdown for chassis outlet 3 is 65C/149F

Note Temperature ranges and values are subject to change.