Cisco Systems ATA 186 manual ReorderTone Parameter Example, 5-35, Component, Setting, Explanation

Models: ATA 186

1 208
Download 208 pages 5.39 Kb
Page 109
Image 109
ReorderTone Parameter Example 2

Chapter 5 Parameters and Defaults

Tone Configuration Parameters

Table 5-5 Reorder Tone Parameter Example 1 Explanation (continued)

Component

Setting

Explanation

 

 

 

NumOfRepeats

0

First on-off pair of the cadence plays once

 

 

(does not repeat), then the second on-off pair

 

 

plays

 

 

 

TotalToneTime

0

Tone plays continuously (set of three on-off

 

 

pairs of the cadence repeat continuously) until

 

 

another call event stops the tone

 

 

 

ReorderTone Parameter Example 2

Assume that you want a reorder tone in which:

The only frequency is 400 Hz.

The frequency plays six times, each time for 0.1 second followed by 0.9 second of silence.

The frequency then plays once for 0.3 second followed by 0.7 second of silence.

The volume of the frequency is –19 dBm.

The tone plays until another call event stops the tone.

For this reorder tone, make the following setting. See Table 5-6for a detailed explanation.

ReorderTone:100,1,31164,1620,0,0,0,0,2,800,7200,2400,5600, 0,0,5,0

Table 5-6 Reorder Tone Parameter Example 2 Explanation

Component

Setting

Explanation

 

 

 

Sequential

100

Required setting for a tone with one frequency

 

 

 

NumOfFreqs

1

One frequency in the tone

 

 

 

TFreq1

31164

First frequency is 400 Hz

 

 

 

TAmp1

1620

First frequency volume is –19 dBm

 

 

 

TFreq2

0

No second frequency

 

 

 

TAmp2

0

No second frequency

 

 

 

TFreq3

0

No third frequency

 

 

 

TAmp3

0

No third frequency

 

 

 

NumOfOnOffPairs

2

Two on-off pairs in the cadence of the tone

 

 

 

OnTime1

800

Sound in first on-off pair plays for 0.1 second

 

 

 

OffTime1

7200

Sound in first on-off pair is followed by 0.9

 

 

second of silence

 

 

 

OnTime2

2400

Sound in second on-off pair plays for 0.3

 

 

seconds

 

 

 

OffTime2

5600

Sound in second on-off pair is followed by 0.7

 

 

second of silence

 

 

 

OnTime3

0

No third on-off pair in the cadence

 

 

 

OffTime3

0

No third on-off pair in the cadence

 

 

 

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide for MGCP (version 3.0)

 

OL-4803-01

5-35

 

 

 

Page 109
Image 109
Cisco Systems ATA 186 manual ReorderTone Parameter Example, 5-35, Component, Setting, Explanation