Appendix C Connecting to DC Power

Wiring the DC-Input Power Source

Figure C-13 Completed Wiring of Terminal Block Plug

1

2

3

4

132850

1

Return (positive) Feed A

3

Return (positive) Feed B

 

 

 

 

2

Supply (negative) Feed A

4

Supply (negative) Feed B

 

 

 

 

Step 8 Insert the terminal block plug in the terminal block header on the front panel of the switch. (See Figure C-14).

Caution Secure the wires coming in from the terminal block so that they cannot be disturbed by casual contact. For example, use tie wraps to secure the wires to the rack.

Figure C-14 Inserting the Terminal Block in the Block Header

SYSTEM

+

+

 

A

 

B

 

INPUT

 

 

 

-36

-72 V

CURRENT

 

 

2 – 1A

CONSOLE

132851

Step 9 Remove the tape from the circuit-breaker switch handle, and move the circuit-breaker handle to the on position.

Cisco ME 3400 Ethernet Access Switch Hardware Installation Guide

 

OL-7677-04

C-11

 

Page 77
Image 77
Cisco Systems Cisco ME 3400 manual Figure C-13 Completed Wiring of Terminal Block Plug