Chapter 2 Using the NetFlow Collector User Interface

Configuration

Active Time

The Active Time value builder obtains a start time and an end time from fields in a flow and calculates the difference. It has the following attributes.

Attribute

Description

 

 

Name

Column name in output.

 

 

Start time field

ID of the start time field to obtain from a flow.

 

 

End time field

ID of the end time field to obtain from a flow.

 

 

Usage

Always leave set as Count.

 

 

Directional Sum

The Directional Sum value builder obtains an integer value from a field in a flow and adds it to a count if the flow direction agrees with what you specify with the Egress attribute. It has the following attributes.

Attribute

Output Name

Field

Egress

Description

Column name in output.

ID of the integer field to obtain from a flow.

Boolean attribute to indicate if flow direction is egress or not.

End Time

The End Time value builder obtains an end time from a field in a flow. It has the following attributes.

Attribute

Name

End time field

Description

Column name in output.

ID of the end time field to obtain from a flow.

Flow Count

The Flow Count value builder increments a count for each flow. It has the following attributes.

Attribute

Name

Usage

Description

Column name in output.

Always leave set as Count.

 

 

Cisco NetFlow Collector User Guide

 

 

 

 

 

 

OL-11399-01

 

 

2-23

 

 

 

 

 

Page 23
Image 23
Cisco Systems OL-11399-01 manual Active Time, Directional Sum, End Time, Flow Count