31-4
Catalyst 3750 SwitchSoftware Configuration Guide
OL-8550-09
Chapter31 Configuring System Message Logging
Configuring System Message Logging
Default System Message Logging Configuration
Table31-2 shows the default system message logging configuration.
Disabling Message Logging
Message logging is enabled by default. It must be enabled to send messages to any destination other than
the console. When enabled, log messages are sent to a logging process, which logs messages to
designated locations asynchronously to the processes that generated the messages.
Table31-2 Default System Message Logging Configuration
Feature Default Setting
System message logging to the console Enabled.
Console severity Debugging (and numerically lower levels; see
Table31-3 on page 31-10).
Logging file configuration No filename specified.
Logging buffer size 4096 bytes.
Logging history size 1 message.
Time stamps Disabled.
Synchronous logging Disabled.
Logging server Disabled.
Syslog server IP address None configured.
Configuration change logger Disabled
Server facility Local7 (see Table31-4 on page 31-14).
Server severity Informational (and numerically lower levels; see
Table31-3 on page 31-10).