9-24
Cisco SCE8000 Installation and Configuration Guide, Rel 3.1.7
OL-16478-02
Chapter 9 Removal and Replacement Procedures
Removing and Replacing Shared Port Adapters
SPAs can be inserted or removed independently from the SIP. Removal of a SIP with installed SPAs is
also supported.
Figure 9-17 illustrates how to install and remove a SPA in the SCE8000-SIP.
Figure 9-17 SPA Installation and Removal
Installing a SPA in a SIP
To install a SPA in a SIP, refer to Figure 9-17 and do the following:
Step 1 At the SCE# prompt, type reload shutdown and press Enter to power down the Cisco SCE8000
platform before installing or removing any module.
Step 2 To insert the SPA in the SIP, locate the guide rails inside the SIP that hold the SPA in place. They are at
the top left and top right of the SPA slot and are recessed about an inch, as shown in Figure 9-17.
Step 3 Carefully slide the SPA all the way in the SIP until the SPA is firmly seated in the SPA interface
connector. When fully seated, the SPA might be slightly behind the SIP faceplate.
Step 4 After the SPA is properly seated, fasten the SPA in place with the captive installation screws.
Removing a SPA from a SIP
To remove a SPA from a SIP, refer toFigure 9-17 and do the following:
Step 1 At the SCE# prompt, type reload shutdown and press Enter to power down the Cisco SCE8000
platform before installing or removing any module.
Step 2 If attached, remove any cables from the SPA.
270988
STATUS
2
0
SPA INTERFACE
PROCESSOR
7600-SIP-400
SPA-1X10GE-L-V2
SPA-1X10GE-L-V2
STATUS
STATUS
1
2
This number... Indicates this component
1 SCE8000-SIP
2 1X10GBE SPA module