9-25
Cisco SCE8000 Installation and Configuration Guide, Rel 3.1.7
OL-16478-02
Chapter 9 Removal and Replacement Procedures
Removing and Replacing the Optical Bypass Module
Step 3 To remove the SPA from the SIP, unfasten the captive installation screws on the SPA.
Step 4 Grasp the handles of the SPA and pull the SPA from the SIP.
Removing and Replacing the Optical Bypass Module
Removing the Optical Bypass Module, page 9-25
Installing the Optical Bypass Module, page 9-25
Replacing the Optical Bypass Module without Disrupting Traffic on the Link , page 9-26
Removing the Optical Bypass Module
Step 1 Disconnect all cables.
Step 2 Loosen the two captive screws on the module.
Step 3 Pull the module out of the slot. Place your other hand under the m odule to support the weight of the
module. Do not touch the module circuitry.
Step 4 Place the module on antistatic foam, or immediately reinstall it in another slot.
Step 5 If the slot is to remain empty, install a module filler plate to keep dust out of the chassis and to maintain
proper airflow through the chassis.
Installing the Optical Bypass Module
Step 1 Remove the module filler plate by loosening the two screws.
Step 2 Insert the module into the opening in the panel. There are no guide rails. Do not touch the module
circuitry.
Step 3 Tighten the two captive screws on the module.
Step 4 Connect the cables as described in Cabling the 10GBE Line Interface Ports: Using the External Optical
Bypass Module, page 6-11.