Chapter 2 Preparation for Installation

Site Requirements

The switch requires a dry, clean, well-ventilated, and air-conditioned environment. To ensure normal operation, maintain ambient airflow. If the airflow is blocked or restricted, or if the intake air is too warm, an overtemperature condition can occur. The switch environmental monitor can then shut down the system to protect the system components.

Multiple switches can be rack-mounted with little or no clearance above and below the chassis. However, when mounting a switch in a rack with other equipment, or when placing it on the floor near other equipment, ensure that the exhaust from other equipment does not blow into the air intake vent of the switch chassis.

Temperature

Temperature extremes can cause a system to operate at reduced efficiency and cause a variety of problems, including premature aging and failure of chips and failure of mechanical devices. Extreme temperature fluctuations can cause chips to become loose in their sockets. Ensure that the system is operating in an environment that does not exceed the specifications in Table A-1 on page A-1. Ensure that the chassis has adequate ventilation. Do not place the chassis within a closed-in wall unit or on top of cloth, which can act as insulation. Do not place it where it will receive direct sunlight, particularly in the afternoon. Do not place it next to a heat source of any kind, including heating vents during winter. Adequate ventilation is particularly important at high altitudes. Make sure that all slots and openings on the system remain unobstructed, especially the fan vent on the chassis. Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat. If the system has been exposed to abnormally cold temperatures, allow a two-hour warm-up period to bring it up to normal operating temperature before turning it on. Failure to do so can damage internal components.

Humidity

High-humidity conditions can cause moisture migration and penetration into the system. This moisture can cause corrosion of internal components and degradation of properties, such as electrical resistance, thermal conductivity, physical strength, and size. Extreme moisture buildup inside the system can result in electrical shorts, which can cause serious damage to the system. Ensure that the system is operating in an environment that does not exceed the specifications in Table A-1 on page A-1. Buildings in which climate is controlled by air-conditioning in the warmer months and by heat during the colder months usually maintain an acceptable level of humidity for system equipment. However, if a system is located in an unusually humid location, a dehumidifier can be used to maintain the humidity within an acceptable range.

Altitude

Operating a system at high altitude (low pressure) reduces the efficiency of forced and convection cooling and can result in electrical problems related to arcing and corona effects. This condition can also cause sealed components with internal pressure, such as electrolytic capacitors, to fail or perform at reduced efficiency. Ensure that the system is operating in an environment that does not exceed the specifications inTable A-1 on page A-1.

Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide

2-2

OL-10853-01

 

 

Page 28
Image 28
Cisco Systems SFS 7000P, SFS 7000D manual Temperature, Humidity, Altitude

SFS 7000D, SFS 7000P specifications

Cisco Systems SFS 7000P is a high-performance storage area network (SAN) solution designed to address the demands of modern data centers. With the continuous growth of data and the increasing need for efficient and secure storage solutions, the SFS 7000P brings forth a blend of innovative technologies and features that facilitate enhanced performance, reliability, and scalability.

One of the main features of the SFS 7000P is its impressive throughput capabilities. The system is optimized for high-speed data processing, enabling organizations to handle large volumes of data efficiently. With support for a range of protocols, including Fibre Channel and Ethernet, the SFS 7000P provides flexibility for integration within diverse IT environments.

Scalability is another characteristic that sets the SFS 7000P apart. Organizations can start with a manageable configuration and expand their storage capabilities as their data needs grow. This modular architecture ensures that investments remain protected and can adapt efficiently to changing business requirements.

In terms of reliability, the SFS 7000P employs advanced redundancy and failover mechanisms. Redundant components within the system, combined with robust data protection software, minimize the risk of data loss and downtime. This is particularly crucial for enterprises that require 24/7 availability for critical applications.

The system supports a range of data management features, including snapshots, replication, and tiered storage. These capabilities provide organizations with the tools to optimize their storage usage, safeguard their data, and ensure seamless disaster recovery options, thereby enhancing overall data resilience.

Furthermore, Cisco has integrated its advanced security technologies into the SFS 7000P, ensuring that data is protected throughout its lifecycle. With stringent access controls and encrypted data transfer capabilities, organizations can secure sensitive information against unauthorized access.

Lastly, the user-friendly interface of the SFS 7000P allows for simple management and monitoring of storage resources. Administrators can efficiently oversee their infrastructure through an intuitive dashboard, enabling quicker responses to issues and better resource allocation.

In summary, Cisco Systems SFS 7000P provides a powerful combination of speed, scalability, reliability, and security. It is an ideal choice for organizations looking to enhance their storage capabilities while ensuring future-proofing against the ever-growing data landscape.