Fru-Error

================================================================

fru-slot fru-error

----------------------------------------------------------------

card(9)

none

card(10)

none

card(11)

none

card(12)

none

card(13)

none

card(14)

none

card(15)

none

card(17)

none

fan(1)

none

fan(2)

none

fan(3)

none

fan(4)

none

power-supply(1) none power-supply(2) none SFS-7000P#

Step 6 Reboot the chassis when the self-test is complete.

SFS-7000P# reload

System configuration is modified. Save? [yes(default) no filename] y

Proceed with reload? [yes(default) no] y

Displaying Hardware Errors

Note The sample text in the steps below shows command output for the Cisco SFS 7000P Server Switch. For the Cisco SFS 7000D Server Switch, you would see a similar display.

To display POST results, non-fatal errors that can are recovered, informational logging (such as firmware updates), and hardware errors follow these steps:

 

 

 

Step 1

Enter the more syslog:hwif_log command to see the contents of the hardware log file.

 

 

 

 

SFS-7000P>

enable

 

 

 

 

SFS-7000P#

more syslog:hwif_log

 

 

 

 

Thu Mar

4

10:57:49 2004: POST: SEEPROM: PASSED

 

 

 

 

Thu Mar

4

10:57:49 2004: POST: FPGA: PASSED

 

 

 

 

Thu Mar

4

10:57:49 2004: POST: SUMMIT: PASSED

 

 

 

 

Thu Mar

4

10:57:50 2004: POST: RTC: PASSED

 

 

 

 

Thu Mar

4

10:57:54 2004: POST: FAN: PASSED

 

 

 

 

Thu Mar

4

10:57:54 2004: card_startup.x : card is starting up

 

 

 

 

Thu Mar

4

10:57:54 2004: Anafa2Init: a2update set to IGNORE

 

 

 

 

Thu Mar

4

10:58:16 2004: Anafa2 POST: firmware check PASSED

 

 

 

 

Thu Mar

4

19:01:55 2004: POST: SEEPROM: PASSED

 

 

 

 

Thu Mar

4

19:01:55 2004: POST: FPGA: PASSED

 

 

 

 

Thu Mar

4

19:01:55 2004: POST: SUMMIT: PASSED

 

 

 

 

Thu Mar

4

19:01:56 2004: POST: RTC: PASSED

 

 

 

 

Thu Mar

4

19:02:00 2004: POST: FAN: PASSED

 

 

 

 

Thu Mar

4

19:02:00 2004: card_startup.x : card is starting up

 

 

 

 

Thu Mar

4

19:02:00 2004: Anafa2Init: a2update set to IGNORE

 

 

 

 

<output truncated>

 

 

 