SFS-7000P-1#show diag post

Chapter 6 Hardware Diagnostic Tests

About Diagnostic Tests

Step 3 Display any errors on individual components by entering the show diag post command.

SFS-7000P-1#show diag post

======================================================================

Post Status

======================================================================

fru-slot post-status post-error

----------------------------------------------------------------------

card(1)

failed

_FRU_LIM_CARDTYPE_ERR

card(3)

failed

_FRU_SEEPROM_PROGRAM_ERR

card(5)

passed

none

card(6)

passed

none

card(7)

passed

none

card(8)

passed

none

card(9)

passed

none

card(11)

failed

_FRU_POWER_CONTROLLER_CONFIG_ERR

card(12)

passed

none

card(13)

passed

none

card(15)

passed

none

card(16)

passed

none

card(17)

passed

none

fan(1)

passed

none

 

 

 

Running Fan Self-Test

The procedures in this section describe the fan module tests and provide sample text from performing a fan test.

Note The sample text in the steps below shows command output for the Cisco SFS 7000P Server Switch. For the Cisco SFS 7000D Server Switch, you would see a similar display.

To perform a diagnostic self-test on a fan, follow these steps:

Step 1 Identify the number of the fan you want to diagnose, if you do not already know the number. Power supply 1 contains fan number 1, and power supply 2 contains fan number 2. (See Figure 6-1.)

Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide

6-4

OL-10853-01

 

 

Page 64
Image 64
Cisco Systems SFS 7000P, SFS 7000D manual Running Fan Self-Test, SFS-7000P-1# show diag post