Cisco Systems SFS 7000P, SFS 7000D manual Running Power Supply Tests, diag, fru-error

Models: SFS 7000D SFS 7000P

1 80
Download 80 pages 61.52 Kb
Page 66
Image 66
Chapter 6 Hardware Diagnostic Tests

Chapter 6 Hardware Diagnostic Tests

Running Power Supply Tests

 

SFS-7000P# show

diag

fan

 

================================================================================

 

Diagnostic Tests For

Fan

 

================================================================================

 

module-type : fan

 

 

module-number :

1

 

 

test : self-test

 

 

 

iterations : 1

 

 

 

action : start

 

 

 

result : success

 

 

 

percentage-completed

: 100

 

result-string : Fan Self Test Completed, Final report : Passed=1, Failed=0, Total=1

 

SFS-7000P#

 

 

Step 4

Display any errors that appear in the result string by entering the show diag fru-errorcommand.

 

SFS-7000P# show

diag

fru-error

 

============================================================

 

 

 

Fru-Error

 

============================================================

 

fru-slot

fru-error

 

------------------------------------------------------------

 

card(1)

none

 

 

card(2)

none

 

 

card(7)

none

 

 

card(8)

none

 

 

card(9)

none

 

 

card(10)

none

 

 

card(11)

none

 

 

card(12)

none

 

 

card(13)

none

 

 

card(14)

none

 

 

card(15)

none

 

 

card(17)

none

 

 

fan(1)

none

 

 

fan(2)

none

 

Step 5

Reboot the chassis when the self-test is complete.

 

SFS-7000P# reload

 

 

System configuration

is modified. Save? [yes(default) no filename] y

 

Proceed with reload?

[yes(default) no] y

 

 

 

 

Running Power Supply Tests

The following tests are available to locate and diagnose fan modules:

LED Test

Self-Test

Note The sample text in this section shows command output for the Cisco SFS 7000P Server Switch. For the Cisco SFS 7000D Server Switch, you would see a similar display.

Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide

6-6

OL-10853-01

 

 

Page 66
Image 66
Cisco Systems SFS 7000P, SFS 7000D manual Hardware Diagnostic Tests Running Power Supply Tests, diag, fru-error